CDB43131-GBK
DS1155V2DB1
55
6.2.3
Measuring Dynamic Range for the CS43131
To measure dynamic range in the WISCE software, click File->Load and select
XTAL_In_ASP_Slave_PCM_Playback_48K_1v7.txt file from {WISCE_INSTALL_FOLDER}/profiles/CS43131 to configure
CS43131 for audio playback in Slave Mode. Note that this method only works when measuring the CSP device. The QFN
device (with mono output) does not interface easily with the CDB-HDR-MEAS board.
6.2.3.1 Measuring Dynamic Range
The following steps show the procedure to measure dynamic range.
1. Place a jumper connecting the 600-
Ω load on J15.
2. Place a jumper connecting the 600-
Ω load on J4.
3. Connect a headphone cable between CSP-HPOUT(J1) and the input of the CDB-HDR-MEAS.
4. Power up the CDB-HDR-MEAS board with ±15V and GND.
5. For each channel, connect a cable between the BNC jacks (Left Channel, Right Channel) and Balanced port on
Analog Inputs 1 and 2 on the APx.
Figure 54 Dynamic Range Setup for CS43131
6. Configure APx and run Dynamic Range Measurement test as described in section 6.2.2.