WIT2450
©
2000- 2005 Cirronet
™
Inc
20
M-2450-0000 Rev B
Setup Example:
1.
Root Setup
: Issue the following commands to the Root, in your system.
wb3
wn = wo = downstream network number = 9
m>
2.
Intermediate Repeater Setup
- Issue the following commands to the Intermediate
Repeater, in your system.
wb2
wn = upstream network number = 9
wo = downstream network number = 8
m>
3.
Last Repeater Setup
- Issue the following commands to the Last Repeater, in your
system.
wb2
wn = upstream network number = 9
wo = downstream network number = XX1
m>
4.
Verify Link
- Verify that each Repeater unit is linked, via DCD indicator. If a unit
is not linked re-check the above settings and run kd4(link status) command, on the
problem unit. It takes a few seconds for the repeaters to synchronize with the system .
5.
Send Data
- With the CSC program on the Repeaters set to Data-Terminal, verify
that you see data on the repeaters, when you type on the Root/Base node, via the CSC
program.
Note:
On the last repeater, the wo value should be set to an unused network number
in your system.