Circutor URBAN M11 Скачать руководство пользователя страница 9

A

Minimum Distances

When installing the unit, respect the minimum distances space for maintenance and 
safety reasons.

Please comply accordingly to your country specifications.

The next picture shows how it should be installed.

• 

Do not install near areas where water or fluids can penetrate into the unit.

• 

Do not install the unit in unstable terrain.

(*) 

If Bollard Impact Protector is installed, keep 500 mm as a minimum distance in 

order to give enough space to open the frontal door of the charge point for maintance 
tasks.

50

500

500

x

*

Measures in mm

09

Installation Guide

URBAN

Содержание URBAN M11

Страница 1: ...URBAN Series INSTALLATION GUIDE M177A01 03 18A...

Страница 2: ...notice CIRCUTOR SA on its web site supplies its customers with the latest versions of the device specifications and the most updated manuals www circutor com Disclaimer Revision log Date Revision Desc...

Страница 3: ...re s your guide to install URBAN 1 So hello 04 2 Before the installation 06 3 Dimmensions and Overview 12 4 Installation 14 5 Technical Data 20 6 Need help 23 7 Guarantee 23 03 Installation Guide URBA...

Страница 4: ...1 04 URBAN Installation Guide...

Страница 5: ...unit Unit must be disconnected from any power source during commissioning ATTENTION Indicates that the damage to property can occur if appropiate precautions are not taken THE FOLLOWING SYMBOLS ARE U...

Страница 6: ...Comply strictly with electrical safety regulations according to your country Do not make repairs or manipulations with the unit energised Only trained and qualified personnel should have access to lo...

Страница 7: ...es 2 POWER SUPPLY LINE DIMENSIONING The dimensioning of the input power supply line of the charge point must be checked by a qualified electrician Note that various factors such as cable length betwee...

Страница 8: ...What s included Charge Point Installation Guide CirCarLife RFID Mifare Card URBAN Post Key Foundation Kit Installation guide 08 URBAN Installation Guide...

Страница 9: ...cture shows how it should be installed Do not install near areas where water or fluids can penetrate into the unit Do not install the unit in unstable terrain If Bollard Impact Protector is installed...

Страница 10: ...Foundation Kit Nuts DIN 934 M16 Washers DIN 9021 M16 Templates Foundation bolts 16x 2x 4x 4x 10 URBAN Installation Guide...

Страница 11: ...ust be placed in the ground taking into consideration the following measures Note In the event of any doubt about the terrain regarding the installation of this unit due to the weight and dimensions i...

Страница 12: ...3 446 438 288 234 1544 1351 113 80 180 Measures in mm 12 URBAN Installation Guide...

Страница 13: ...5 6 1 Hat 2 LED Beacons 3 Display RFID Reader 1 4 Socket 2 5 Key lock access 6 Base 1 Only URBAN M21 URBAN T21 URBAN M22 URBAN T22 URBAN T22 C and URBAN T24 MIX 2 Sockets may vary depending on the mo...

Страница 14: ...4 A 1 2 Opening Use provided key in order to open the unit 14 URBAN Installation Guide...

Страница 15: ...Installation B Positioning 1 Remove the template nuts before proceeding 2 Place the charge point through the four foundation bolts 15 Installation Guide URBAN...

Страница 16: ...Firmly tighten the 4 nuts using a 24mm open end wrench C Fixation 16 URBAN Installation Guide...

Страница 17: ...It is recommended to install a cable glands not supplied in pre holes position Assembly metal plate using the 4 supplied screws as shown below 4x D Metal plate 17 Installation Guide URBAN...

Страница 18: ...onnect to the 400V If the Power Supply is Single Phase connect L1 and N S Note The proper earthing system must be TT or TN S The ground loop impedance measurement for the entire installation must be l...

Страница 19: ...4 CHECK THE CONNECTORS Connectors should be in good conditions before starting the unit 5 ELECTRICAL PROTECTIONS Rearm all the protections installed on the unit 6 CHECK THE BEACON INDICATORS All beac...

Страница 20: ...Type 2 socket A CEE 7 3 socket B Charging Mode Mode 3 Mode 3 socket A B Mode 3 socket A Mode 1 2 socket B Overcurrent protection MCB 40A Curve C MCB 40A Curve C socket A B MCB 40A Curve C socket A MCB...

Страница 21: ...N PE 3P N PE 1P N PE 3P N PE Input voltage 230V 10 400V 10 230V 10 400V 10 Input Current 35 A 67 A Frequency 50Hz 60Hz Number of sockets 1 2 Socket A Socket B 4 2 2 socket A 2 socket B Maximum socket...

Страница 22: ...e 20 C 60 C Operating humidity 5 95 Non condensing MECHANICAL DATA Enclosure rating IP54 IK10 Enclosure material Aluminium ABS Enclosure door Frontal key locked door Net weight 55Kg Dimensions W x H x...

Страница 23: ...the storage installation and maintenance instructions listed in this manual have not been fol lowed Improper usage is defined as any operating or storage condition contrary to the national electrical...

Страница 24: ...CIRCUTOR SA Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 34 93 745 29 00 Fax 34 93 745 29 14 www circutor com central circutor com...

Отзывы: