Technical Data
MECHANICAL DATA
Enclosure rating
IP54 / IK10
Enclosure material
Aluminium & ABS
Enclosure door
Frontal key locked door
Net weight
55Kg
Dimensions (W x H x D)
450 x 1550 x 290 mm
Min. cable section
M11
T11
M12
T12
T12-MIX
10 mm
2
25 mm
2
16 mm
2
STANDARDS
IEC 61851-1: 2010, IEC 61851-22: 2001, IEC 62196-1: 2014, IEC 62196-2: 2011, 2014/35/UE, LVD;2014/30/UE, ISO
14443A/B
B
URBAN M21, URBAN T21, URBAN M22, URBAN T22, URBAN T22-C,
URBAN T24-MIX
ELECTRICAL DATA
M21
T21
M22
T22
T22-C
T24-MIX
Power supply
1P+N+PE
3P+N+PE
1P+N+PE
3P+N+PE
Input voltage
230V~± 10%
400V~± 10%
230V~±10%
400V~±10%
Input Current
35 A
67 A
Frequency
50Hz / 60Hz
Number of
sockets
1
2 : Socket A, Socket B
4
(2)
: 2 socket A,
2 socket B
Maximum
socket Power
7.4 kW
22 kW
7.4 kW
(socket A & B)
22 kW
(socket A & B)
22 kW / 3.7 kW
(socket A & B)
Maximum
socket
current
32 A
32 A (socket A & B)
32 A / 16 A
(socket A & B)
Connectors
type
Type 2
Type 2 (socket A & B)
Type 2 / CEE 7/3
(socket A & B)
Charging
Mode
Mode 3
Mode 3(socket A & B)
Mode 1. 2 & 3
(socket A & B)
Overcurrent
protection
MCB 40A (Curve C)
MCB 40A (Curve C)
(socket A & B)
MCB 40A / 16 A
(Curve C)
(socket A & B)
Safety
RCD 30 mA (Type A) / (Type B)
(1)
Surge
protection
(1)
Transient surge protector IEC 61643-1 (Class II)
21
Installation Guide
URBAN
Содержание URBAN M11
Страница 1: ...URBAN Series INSTALLATION GUIDE M177A01 03 18A...
Страница 4: ...1 04 URBAN Installation Guide...
Страница 12: ...3 446 438 288 234 1544 1351 113 80 180 Measures in mm 12 URBAN Installation Guide...
Страница 14: ...4 A 1 2 Opening Use provided key in order to open the unit 14 URBAN Installation Guide...
Страница 16: ...Firmly tighten the 4 nuts using a 24mm open end wrench C Fixation 16 URBAN Installation Guide...