background image

 11�- USAGE AND MAINTENANCE

 11.1 - INSTALLATION

Before the assembly of the canopies, the technical management of the works or the engineering 

company  that  carries  out  the  installation  project  must  draft  a  technical  project  in  which  the 

housings (foundations, footings, support structure, etc.) are sized accordingly with the resulting 

stressed exerted on the canopy due to wind and snow indicated by the regulations applicable 

to the specific location of the canopy.

11�1�1�- ASSEMBLY ACCORDING TO MANUFACTURER SPECIFICATIONS

The canopies must be assembled following the instructions in this assembly manual. Under no 

circumstances may parts or pieces be modified, or steps omitted.

11�1�2�- DIFFICULTIES AND VARIATIONS DURING ASSEMBLY

Any damage detected during the assembly, either as a result of the actual process or if any part 

does not match those described in the manual, must be notified of to the company supplying 

the structure.

11�1�3�- BONDING OF PARTS AND TIGHTENING TORQUE

All joints of the canopy’s parts must be made with the supplied screws and nuts. Any change of 

screws and nuts must be communicated and authorised by the manufacturer.

The tightening torques of the joints must be checked according to the following specifications:

M8

 = between 16 and 19 Nm  

M10

 = between 33 and 39 

M20

 = between 182 and 274 Nm

M24

 = between 264 and 324 Nm

11�1�4�- FOUNDATIONS, ALIGNMENT AND LEVELLING OF THE CANOPIES

The foundations must be made with the material supplied by the manufacturer and according 

to the specifications described in this manual. 

The legs must be aligned and level.

In the event that these requirements cannot be met due to the type of installation, please notify 

the manufacturer to study the situation and behaviour of the canopy.

Any installation made on sloping terrain should be specifically studied to ensure the proper 

functioning of the canopy.

11�1�5�- LOCATION AND CHARACTERISTICS OF THE INSTALLATION ZONE

The  canopies  have  been  studied  to  be  installed  free  of  any  building  or  nearby  walls.  If  an 

adjacent wall is installed, a special study will be required to vary the coefficient of obstruction 

contemplated in the calculation.

40

PVS2

Installation Guide

Содержание PVS2

Страница 1: ...INSTALLATION GUIDE M273A01 03 19A Canopies PVS2...

Страница 2: ...2 PVS2 Installation Guide...

Страница 3: ...he following should be taken into consideration Incorrect handling or installation of the unit may result in injury to personnel as well as damage to the unit In particular handling with voltages appl...

Страница 4: ...OF EARTHING POINT 27 8 PROFILES AND MODULES 28 8 1 INTERMEDIATE PROFILES 28 8 2 FINAL PROFILES 28 8 3 PREPARATION OF PROFILES 29 8 4 FITTING OF INTERMEDIATE PROFILES 1 30 8 5 FITTING OF INTERMEDIATE...

Страница 5: ...11 3 2 REVISION AND MAINTENANCE TASKS 42 11 3 3 CASES THAT INVOLVE SPECIAL REVIEWS 43 12 MAINTENANCE AND TECHNICAL SERVICE 44 5 Installation Guide PVS2...

Страница 6: ...able 1 Revision log Date Revision Description 08 19 M273A01 01 19A Initial version Note The images of the devices are for illustrative purposes only and may differ from the original device 6 PVS2 Inst...

Страница 7: ...ms and conditions expressed below Exclusions and Limitations of Guarantees Those damages and faults established herein will be exempt from the warranty rights whenever these arise from 1 Accidents or...

Страница 8: ...is not allowed nor in general any added element that increases the surface exposed to the wind Only the assembly of original parts and components supplied by CIRCUTOR is allowed CIRCUTOR will not be h...

Страница 9: ...2 3 5 17 2 5 7 8 11 PVS2 3 3 5 17 2 5 7 8 11 PVS2 4 3 5 17 2 5 7 8 11 PVS2 5 3 5 17 2 5 7 8 11 PVS2 6 3 5 17 2 5 7 8 11 PVS2 8 3 5 17 2 5 7 8 11 PVS2 10 3 5 17 2 5 7 8 11 Figure 2 PVS2 models 9 Insta...

Страница 10: ...odules Feet PVS2 2 5 0 m 4 20 kWp 15 1 PVS2 3 8 0 m 6 72 kWp 24 2 PVS2 4 10 0 m 8 40 kWp 30 2 PVS2 5 13 0 m 10 92 kWp 39 2 PVS2 6 15 0 m 12 60 kWp 45 3 PVS2 8 20 0 m 16 80 kWp 60 3 PVS2 10 25 0 m 21 0...

Страница 11: ...4 COMPONENTS M WING FOOT PPV10APLI BEAM Figure 3 PVS2 components 11 Installation Guide PVS2...

Страница 12: ...20X280 M10 M24 Zn M24 M20 M24 17u 16u 24u 4u 26u 8u DIN 603 M10X25 M10X50 8u 8u M20 17u RIGHT VIEW LEFT VIEW M239700000000 WING START M326100000000 PV ANGLE BEAM C M302100000000 V WING ANGLE M2L570000...

Страница 13: ...000001 TORN M104200000005 M106200000001 M108A00000000 TORN PVS2 2 15 4 4 2 0 0 24 10 60 12 12 PVS2 3 24 4 7 0 0 2 36 16 96 18 18 PVS2 4 30 4 9 2 2 0 52 20 120 22 22 PVS2 5 39 4 12 2 0 0 56 26 156 24 2...

Страница 14: ...to recharging point in start foot AC wiring Figure 4 Standard installation with recharging point in start foot 5 1 2 STANDARD INSTALLATION WITH RECHARGE POINT IN START AND END FOOT Lowering of strings...

Страница 15: ...ral foot Power supply of recharging points in each foot AC wiring Figure 6 Major installation 5 1 4 INTERNAL CONNECTION OF FEET STRINGS CONDUCTION OF DC WIRING THROUGH THE BEAMS EARTH CONNECTION SEE P...

Страница 16: ...GTH OF 6 M APPROXIMATELY FROM CASKET SPLICE FOR THE LOWERING OF STRINGS DC WIRING IF IT IS ONLY FOR AC WIRING OF THE CHARGER PROJECTION OF 4 M APPROXIMATELY OF CASKET SPLICE LEAVE CABLES IN PLACE CASK...

Страница 17: ...5 3 EARTH CONNECTION ON EACH FOOT CASKET FOOT TUBE Figure 9 Earth connection 5 4 ASSEMBLE TEMPLATES Torque kp m 71 M24 36x 50 50 500 950 Figure 10 Assembly of templates 17 Installation Guide PVS2...

Страница 18: ...5 5 FILLING THE FOOTINGS Figure 11 Filling the footings 5 6 REMOVE UPPER TEMPLATE Figure 12 Remove upper template 18 PVS2 Installation Guide...

Страница 19: ...6 ASSEMBLY OF FEET AND WINGS 6 1 FOOT INSTALLATION A Torque kp m 71 M24 D24 6x 6x PULL PIPES WHEN LIFTING DO NOT STEP ON TUBES OR PIPES Figure 13 Foot installation A 19 Installation Guide PVS2...

Страница 20: ...6 2 FOOT INSTALLATION B Torque kp m 71 M24 D24 6x 6x Figure 14 Foot installation B 20 PVS2 Installation Guide...

Страница 21: ...6 3 INSTALLATION OF FEET REINFORCEMENT 1x UPPER VIEW Figure 15 Installation of foot reinforcement 21 Installation Guide PVS2...

Страница 22: ...6 4 INSTALLATION OF WINGS A Torque kp m 71 DIN 931 M20X280 M20 7x 14x 7x Figure 16 Installation of wings A D20 22 PVS2 Installation Guide...

Страница 23: ...6 5 ALIGNMENT OF THE FEET X Y X Y X Y X Y Figure 17 Alignment of the feet 23 Installation Guide PVS2...

Страница 24: ...7 ASSEMBLY OF BEAMS 7 1 FITTING OF ANGLES 3x 1x Figure 18 Fitting of angles 24 PVS2 Installation Guide...

Страница 25: ...7 2 BEAM ANGLES Torque kp m 71 DIN 931 M20X130 M20 4x 4x Figure 19 Beam angles 25 Installation Guide PVS2...

Страница 26: ...7 3 FITTING OF BEAMS Torque kp m 3 8 M10X25 M10x50 M10 2x 4x 2x Figure 20 Fitting of beams 26 PVS2 Installation Guide...

Страница 27: ...7 4 INSTALLATION OF EARTHING POINT Torque kp m 3 8 M10X25 M10 1x 1x INSIDE VIEW OF THE INSTALLATION PIE Figure 21 Installation of earthing point 27 Installation Guide PVS2...

Страница 28: ...IATE PROFILES 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 M103200000002 S273200000001 Figure 22 Intermediate profiles 8 2 FINAL PROFILES 3 4 M109200000002 S268100000001 3 4 3 3 3 3 3 3 Figure 23 Final p...

Страница 29: ...3 PREPARATION OF PROFILES A Torque kp m 3 8 M10X25 M10 M14 4x 4x 4x Figure 24 Preparation of profiles A B Torque kp m 3 8 M8X10 M8 1x 1x Figure 25 Preparation of profiles B 29 Installation Guide PVS2...

Страница 30: ...8 4 FITTING OF INTERMEDIATE PROFILES 1 1 M103200000002 Torque kp m 3 8 Figure 26 Fitting of intermediate profiles 1 30 PVS2 Installation Guide...

Страница 31: ...8 5 FITTING OF INTERMEDIATE PROFILES 2 2 S273200000001 Figure 27 Fitting of intermediate profiles 2 31 Installation Guide PVS2...

Страница 32: ...8 6 FITTING OF FINAL PROFILES 3 3 M109200000002 M109200000002 Figure 28 Fitting of final profiles 3 32 PVS2 Installation Guide...

Страница 33: ...8 7 FITTING OF FINAL PROFILES 4 4 S268100000001 Figure 29 Fitting of final profiles 4 33 Installation Guide PVS2...

Страница 34: ...8 8 SETTING MODULES A POSITION OF CONNECTION BOX SEE POINT 8 10 M106200000001 M104200000006 Figure 30 Setting modules A 34 PVS2 Installation Guide...

Страница 35: ...8 9 SETTING MODULES B GPV10APLI TPV10APLI POSITION OF CONNECTION BOX SEE POINT 8 10 Figure 31 Setting modules B 35 Installation Guide PVS2...

Страница 36: ...Distribute the modules according to their connection as per the following scheme 1 2 2 3 3 4 1 2 3 4 1 2 3 4 DC WIRING CHANNEL THROUGH THE BEAMS AND INSIDE OF THE FOOT Figure 32 Connection of strings...

Страница 37: ...9 FINAL FOUNDATIONS Hormig n Concrete Figure 33 Final foundations 37 Installation Guide PVS2...

Страница 38: ...10 INSTALLATION OF THE CHARGER Remove the covers stamped to insert the charger Figure 34 Installation of the charger Step 1 38 PVS2 Installation Guide...

Страница 39: ...Figure 35 Installation of the charger Step 2 39 Installation Guide PVS2...

Страница 40: ...of the canopy s parts must be made with the supplied screws and nuts Any change of screws and nuts must be communicated and authorised by the manufacturer The tightening torques of the joints must be...

Страница 41: ...ultation with the specialist technician especially in the case of changes in use Should these be exceeded there would be depletion in the structure leading to deformations and breaks People will not b...

Страница 42: ...guidelines must be adjusted and if necessary these must be changed periodically according to the conditions of service and the product s alteration over time 11 3 2 REVISION AND MAINTENANCE TASKS 11 3...

Страница 43: ...s or any other cause a remediation of the point with rust will be carried out immediately and a product will be applied to provide sufficiently accredited protection in the affected area This periodic...

Страница 44: ...o device operation or malfunction please contact the CIRCUTOR SA Technical Support Service Technical Assistance Service Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 902 449 459 Espa a 34 937...

Страница 45: ...45 Installation Guide PVS2...

Страница 46: ...CIRCUTOR SA Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 34 93 745 29 00 Fax 34 93 745 29 14 www circutor es central circutor com...

Отзывы: