background image

Figure 68: Google screen: New project�

5�-

 Add a subject name and make a note of it, as it will be used later on.

Figure 69: Google screen: Create a subject�

6�-

 Create certificates.

Before creating the device registry, an RS256 key has to be generated with a self-signed X.509 

certificate. The X.509 certificate must be valid when creating or updating a device or an error will be 

generated. 

By default, X.509 certificates expire 30 days after creation.

To generate a private RSA-256 key with a key size of 2048 bits and a self-signed X.509 certificate, 

enter the following command:

openssl req -x509 -nodes -newkey rsa:2048 -keyout rsa_private�pem -out rsa_cert�pem -subj “/CN=unused”

57

Instruction Manual

line-EDS-Cloud

Содержание line-EDS-Cloud

Страница 1: ...INSTRUCTION MANUAL M231B01 03 22A Access point line EDS Cloud...

Страница 2: ...2 line EDS Cloud Instruction Manual...

Страница 3: ...llowing should be taken into consideration Incorrect handling or installation of the unit may result in injury to personnel as well as damage to the unit In particular handling with voltages applied m...

Страница 4: ...1 USAGE ENVIRONMENT AND HEALTH 18 5 2 2 Wi Fi COMMUNICATIONS 18 6 CONFIGURATION WEBSITE 19 6 1 CONFIGURATION OF THE line EDS Cloud DEVICE 20 6 1 1 COMMUNICATION DNS NTP SETTINGS 21 6 1 2 COMMUNICATION...

Страница 5: ...s 6 6 1 3 6 1 4 6 2 6 4 6 6 2 Note The images on the devices are for illustrative use only and may differ from the original device SYMBOLS Table 2 Symbols Symbol Description In accordance with the rel...

Страница 6: ...reception immediately contact the transport com pany and or CIRCUTOR s after sales service 2 PRODUCT DESCRIPTION line EDS Cloud is a device that works as connector between field devices with Modbus R...

Страница 7: ...to heed the warnings and or recommendations set out in this manual nor for damage resulting from the use of non original products or accessories or those made by other manufacturers Do not use the dev...

Страница 8: ...ates how the panel adapter connects to a line EDS Cloud Before installing the adapter the device must be disconnected from all power and measurement supplies Figure 1 Installation of the panel adapter...

Страница 9: ...loud devices can be expanded with other devices in the line range the line CVM and line M expansion modules The line EDS Cloud and line CVM devices enable up to 2 expansion modules to be directly conn...

Страница 10: ...d side of the devices to be fed It can supply up to 10 VA allowing it to power a limited number of devices The maximum set it can supply is 1 line EDS Cloud 1 line CVM 1 line M Figure 6 line EDS line...

Страница 11: ...ewdriver remove the expansion connector s protective covers located on the side of the devices Figure 8 Figure 8 Installation step 1 2 Insert the expansion connector and fastening clips into one of th...

Страница 12: ...stallation of all devices please refer to the instruction manual for the different models M237B01 01 xxx Instruction Manual for line CVM devices M239B01 03 xxx Instruction Manual for line M expansion...

Страница 13: ...SERVIDOR SERVER With a browser compatible with HTML5 With a browser compatible with HTML5 Con navegador Web compatible con HTML5 Con navegador Web compatible con HTML5 LAN WLAN SLAVES line EDS A B S...

Страница 14: ...nds data to Cloud platforms The parameters that you want to upload to the Cloud platform can be selected on the device s configuration website The device currently works with the following Cloud platf...

Страница 15: ...n Table 7 WLAN LED LED Description WLAN On blue color Connection to a Wi Fi network Flashing blue color Activity in the Wi Fi network ALARM Table 8 ALARM LED LED Description CPU On red color Alarm act...

Страница 16: ...uts optoisolator NPN transistors terminals 19 20 and 21 in Figure 3 19 Carga Load Fuente externa External load Salidas de transistor Transistor outputs 21 1 2 C LAN WLAN SLAVES line EDS Figure 13 Digi...

Страница 17: ...ith mesh shield minimum 3 wires with a maximum distance of 1200 meters between the line EDS Cloud and the slave devices In this bus we can connect a maximum of 32 slave devices RS 485 A B S A B S LAN...

Страница 18: ...devices implanted in the human body pacemak ers etc In any other setting where the risk of interference with other devices or services is a hazard If you are not sure of the applicable usage policy f...

Страница 19: ...0 0 0 1 with a subnet mask 255 255 255 0 To access the configuration website open the screen shown in Figure 15 where you enter the User and Password The default values are shown in Table 11 Figure 15...

Страница 20: ...vices connected Setting up the rules of action of the various connected devices Figure 17 Menu of configuration website On the configuration website you can perform 3 main actions Configure the line E...

Страница 21: ...are configured DHCP If DHCP is enabled the IP address is dynamically assigned by a central server and no further parameters need to be configured If this option is disabled the IP address is fixed and...

Страница 22: ...displayed when the line EDS Cloud is connected to a line M 3G a device that adds 3G connectivity to the line EDS Cloud device Figure 20 Figure 20 Configuration Dynamic DNS Select to enable or not a d...

Страница 23: ...elected Wi Fi network Status Wi Fi status IP Network IP address MAC address MAC address of the device non configurable parameter Press to save the configuration and send it to the device 6 1 6 SECURIT...

Страница 24: ...LOUD PLATFORM On the Profiles screen you can create the profile and memory map of the data you want to up load to the Cloud platform Figure 23 Figure 23 Profile screen On this screen you can Create a...

Страница 25: ...les Figure 25 Figure 25 Profiles Variables VARIABLES tab In this tab the memory locations variables in a Modbus map can be created that will be part of the profile When you press the Add new variable...

Страница 26: ...cale factor Multiplication factor Note Variable visible when selecting types in Type UINT8 UINT16 UINT32 UINT64 INT8 INT16 INT32 and INT64 Precision Select the number of decimal places to be shown Not...

Страница 27: ...pload to the Cloud platform can be entered on the Devices screen Figure 28 Figure 28 Device screen On this screen you can Add a new device to the system Delete a device Enable or disable a device in t...

Страница 28: ...nication ModbusRTU or ModbusTCP When selecting the ModbusRTU communication type the following parameters have to be configured Baudrate Select the communications baud rate 9600 19200 38400 57600 11520...

Страница 29: ...duler the data to be uploaded from each device can be programmed as well as the frequency of uploads to the Cloud platform Figure 31 Figure 31 Schedule screen On this screen you can Add a new schedule...

Страница 30: ...e new schedule STEP 4 SPECIFY THE CLOUD PLATFORM TO WHICH THE DATA WILL BE UPLOADED The Cloud platform to which the data will be uploaded is specified on screen Exports Figure 33 Figure 33 Exports scr...

Страница 31: ...ou have to configure Name Name of the data upload Address Platform address Object Object created from the Amazon Web Services AWS platform Certificate Upload certificate file Key Upload file with the...

Страница 32: ...g the relationship between the line EDS Cloud device and the platform in the Cloud where you want to export the data you have obtained Once the configuration steps for the upload system have been comp...

Страница 33: ...ead Instantaneous Average Minimum or Maximum Click to save the new schedule 6 4 RULES The Rules screen lets you add actions to the devices based on programmed conditions Figure 37 Figure 37 Rules On t...

Страница 34: ...rs the condition Operator select the operator Equal Different Value value that the variable must satisfy to add a new condition that must be met together with the first condition to trigger the action...

Страница 35: ...cted upon Command select the command to be acted upon Action select the action Add action to add different actions to carry out when the conditions are met Press to save the new rule 6 5 HISTORIC The...

Страница 36: ...r and firmware version Figure 41 If a name is entered in the Name parameter all the information on the device can be saved by clicking You can also to update the device firmware 1 Download the update...

Страница 37: ...reload the event log 6 6 3 STATUS This section Figure 43 shows the device status Figure 43 System Status 6 6 4 RESTART In this section Figure 44 the line EDS Cloud device can be reset by clicking the...

Страница 38: ...9200 38400 57600 115200 bps Data bits 8 Stop bits 1 2 Parity without even odd Ethernet communication Type Ethernet 10BaseT 100BaseTX self detectable Connector RJ45 Protocol Web server MQTT REST Connec...

Страница 39: ...netic compatibility EMC Part 6 4 Generic standards Emission standard for industrial environments EN 61000 6 4 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use Pa...

Страница 40: ...proper installation or improper usage of the unit Consequently this guarantee does not apply to failures occurring in the following cases Overvoltages and or electrical disturbances in the supply Wate...

Страница 41: ...nd CIRCUTOR The object of the declaration is in conformity with the relevant EU harmonisation legislation provided that it is installed maintained and used for the application for which it was manufac...

Страница 42: ...M EXT PS line M 20I line M 3G line TCPRS1 Marca CIRCUTOR O objeto da declara o est conforme a legisla o de harmoniza o pertinente na UE sempre que seja instalado mantido e utilizado na aplica o para...

Страница 43: ...iot deklaracji jest zgodny z odno nymi wymaganiami prawodawstwa harmonizacyjnego w Unii Europejskiej pod warunkiem e b dzie instalowany konserwowany i u ytkowany zgodnie z przeznaczeniem dla kt rego z...

Страница 44: ...are as follows 1 On the configuration website of the device open the Exports screen where the Cloud platform can be defined Press Add export to select and configure the Cloud platform the screen show...

Страница 45: ...ispositivo Add Device add the line EDS Cloud enter a name the device type and select the Es puerta de entrada It s an input gateway option Figure 48 MyCircutor platform Add Device 4 Once line EDS Clou...

Страница 46: ...specify the Access token for the device Figure 50 MyCircutor Platform Access token 6 Copy the Token and enter it into the configuration website of the device Figure 46 7 Once the data export to MyCirc...

Страница 47: ...following values Format Select Amazon Address The information for this field is obtained on the AWS platform Object The information for this field is obtained on the AWS platform Certificate The infor...

Страница 48: ...d click Crear Figure 54 AWS platform Objects 4 Several steps are required to create an object 4 1 On the screen Creaci n de objetos de AWS IoT Creation of AWS IoT objects click on the option Crear un...

Страница 49: ...reen A adir un certificado para el objeto Add a certificate for the object click Crear un certificado Create a certificate to create the object and the certificates Take note of the location in which...

Страница 50: ...gnar un Nombre Name and add a security configuration If we do not know the appropriate configuration for our case we can select Advanced Mode and use the following minimum security configuration Versi...

Страница 51: ...nistraci n Administration Objetos Objects and click on the object created previously Figure 60 AWS platform Administration Objects 6 2 Select Seguridad Security and click on the certificate created 6...

Страница 52: ...e list of possible policies and click Asociar 6 5 Finally click Activar 7 Enter the new data on the device configuration website Figure 62 Export Screen Add Export Address This field is in the Interac...

Страница 53: ...ta export to the Amazon Web Services AWS platform has been configured the readings of the values from the devices associated with the line EDS Cloud are shown on the platform To do this in the AWS IoT...

Страница 54: ...Figure 64 AWS platform Shadow 54 line EDS Cloud Instruction Manual...

Страница 55: ...e the Cloud platform the screen shown in Figure 65 will appear Figure 65 Export Screen Add Export 2 To fill in all the above fields you need to log into the Google Cloud IoT Core platform And create a...

Страница 56: ...Project Name and an ID in ID del proyecto Project ID Make a note of the ID as it will be used later Figure 67 Google screen New project 4 Configure a Pub Sub communication To do this in the Big Data...

Страница 57: ...elf signed X 509 certificate The X 509 certificate must be valid when creating or updating a device or an error will be generated By default X 509 certificates expire 30 days after creation To generat...

Страница 58: ...7 Creating a device registration 7 1 In the menu Big Data go to IoT Core Figure 70 Google screen Google Cloud Platform IoT Core 7 2 Enable API Figure 71 Google screen Enable API 7 3 Press Crear regist...

Страница 59: ...igure 72 Google screen Create a registry ID de registro Make a note of this as it needs to be used in the line EDS Cloud configuration Regi n Select the nearest one 59 Instruction Manual line EDS Clou...

Страница 60: ...ctions ID de Dispositivo Make a note of this as it needs to be used in the line EDS Cloud configuration Comunicaci n de Dispositivo Select Permitir Autenticaci n In M todo de introducci n Introduction...

Страница 61: ...e Cloud IoT Core platform into the device configuration website 10 Once the data export to the Google Cloud IoT Core platform has been configured the readings for the values from the devices linked to...

Страница 62: ...igation menu go to Big data IoT Core and select the registry and the device created The dates of the last data sets received are displayed on the screen Figure 75 Google screen Device 62 line EDS Clou...

Страница 63: ...63 Instruction Manual line EDS Cloud...

Страница 64: ...CIRCUTOR SA Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 34 93 745 29 00 Fax 34 93 745 29 14 www circutor es central circutor com...

Отзывы: