21
Instructions Manual
GETEST
≥ 40 m
1 m
5 A
Auxiliary ground
Hardware ground
Measuring
electrodes
Access door
Figure 14: Contact voltage Test connection�
4�-
Ensure the electrodes are stable.
Despite featuring a non-slip design, the electrodes can slide on the surface. Make sure
they are stable before using them.
5�-
Stand on the electrodes, stepping inside the marked surface,
.
Figure 15: Stand on the electrodes�
Always wear non-conducting safety footwear when using the electrodes.
Always stand inside the marked area.
6�-
Keep your body in a fixed position that avoids motion during the measurements.
Keep an upright and relaxed position while standing on the electrodes.
For a correct measurement, the weight of the person must be at least
50 kg
.