The 

CDP

 and the inverter communicate via an RS-485 bus. This RS-485 bus can connect up 

to 32 inverters, although the number of inverters in the vast majority of domestic installations 

ranges from 1 to 3.

 2.1.- COMMUNICATION CABLE

To communicate with a 

KOSTAL PIKO

 inverter using a 

CDP

, the inverter must be equipped 

with a communications card with an RS-485 interface (

Figure 1

). 

Figure 1:Communication card.

Table 3:Communication card.

No

Description

1

Connection terminal S0/AL-Out (2-pole)

2

2 Ethernet connections (RJ45)

3

Analog interface connection terminal

4

Connection terminal for RS-485 interface

5

Extension module connection terminal

The connector is a terminal for a 0.25mm

2

 cable

Functions of the communication cable terminals between the 

CDP

 and the inverter:

Table 4:

 Functions of the communication cable terminals

.

CDP

R2 channel communications 

connector

Communication card

RS-485 Terminal (No. 4)

Terminal

Description

Terminal

Description

A+

A+

RS-485 A +

B-

B-

RS-485 B -

GND

GND

GND

It is not necessary to wire the GND terminal, although it is advisable to do so for long distances.

Содержание CDP-0

Страница 1: ...APPLICATION NOTES Connection and configuration of a CDP with KOSTAL inverters M028E0401 03 19A...

Страница 2: ...2 CDP Application notes...

Страница 3: ...prior to connecting the unit Follow all installation and maintenance instructions throughout the unit s working life Pay special attention to the installation stan dards of the National Electrical Cod...

Страница 4: ...CONNECTION OF ONE INVERTER 8 2 1 2 CONNECTION OF SEVERAL INVERTERS 8 2 2 INVERTER COMMUNICATION CONFIGURATION 8 2 2 1 COMMUNICATION BETWEEN THE INVERTER AND THE PC BY ETHERNET CABLE 10 2 2 2 CONFIGUR...

Страница 5: ...e images of the units are solely for the purpose of illustration and may differ from the original unit SYMBOLS Table 2 Symbols Symbol Description In compliance with the relevant European directive Dev...

Страница 6: ...a substitute for the CDP or inverter manuals but rather as additional support for individuals who need to interconnect the two devices Even so the guides and manuals of each product should be consult...

Страница 7: ...ation card No Description 1 Connection terminal S0 AL Out 2 pole 2 2 Ethernet connections RJ45 3 Analog interface connection terminal 4 Connection terminal for RS 485 interface 5 Extension module conn...

Страница 8: ...the following configuration Table 5 Table 5 Communications cable connection Inverter 1 cable end Inverter 3 cable end Inverter n cable end A A A B B B GND GND GND 2 2 INVERTER COMMUNICATION CONFIGURA...

Страница 9: ...communications card Programming the inverter on the web server is recommended given that it streamlines the pro gramming and enables a faster and easier configuration The parameters to be configured a...

Страница 10: ...tton until you reach the Network 2 Configuration option Press Enter This window shows the current IP address of the inverter See the chapter on how to access the web server in the inverter manual 2 2...

Страница 11: ...11 Application notes CDP Figure 7 KOSTAL inverter configuration screen...

Страница 12: ...ameters of the connected invert er have to be entered To do so enter setup at the end of the navigation bar where the CDP is monitoring so that the following for example appears in the navigation bar...

Страница 13: ...in the CDP so that the same regulation percentage is sent to each one When working with single phase inverters in three phase installations the total power of all the inverters must be programmed by s...

Страница 14: ...he number of inverters MUST be programmed using the CDP SETUP web site Correct communication between the CDP and the inverters connected to it can be checked on the configuration web site To do so pre...

Страница 15: ...ting 1400 W This value can be seen on the inverter display Next program the CDP indicating that the inverter power is 6000 W The CDP will send the inverter a new setpoint so it can change its MPPT and...

Страница 16: ...ved from a pos sible failure improper installation or improper usage of the unit Consequently this guarantee does not apply to failures occurring in the following cases Overvoltages and or electrical...

Страница 17: ...17 Application notes CDP...

Страница 18: ...CIRCUTOR SA Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 34 93 745 29 00 Fax 34 93 745 29 14 www circutor es central circutor com...

Отзывы: