SAFETY INFORMATION

This meter is CUL and UL approved and conforms to IEC 61010-1 for Cat-

egory III - 600V and Category II - 1000V. This meter is designed to be safe 

under the following conditions: indoor use, altitude up to 2000m, temperature 

5°C to 40°C, maximum relative humidity 80% for temperatures up to 31°C 

decreasing  linearly  to  50%  relative  humidity  at  40°C  and  rated  pollution 

degree  2.  Caution  and  proper  guidelines  must  be  followed  for  personal 

and product safety. Read this instruction manual carefully and completely 

before using the meter. Lack of caution or poor safety practices can result 

in serious injury or death.
•  This meter is not recommended for high voltage industrial use; for 

example, do not use for measurement on 440VAC or 600VAC industrial 

power mains. The unit is intended for use with low energy circuits up to 

600VDC / 600VAC or high energy circuits up to 250VAC / 250VDC only. 

•  Use caution when working above 60VDC or 30VAC RMS as these volt-

ages pose a shock hazard.

•  Always consider circuits to be energized. Never assume any equipment 

to be de-energized. 

•  Always start with power off. Set the function switch to the correct setting 

before making any measurements and do not change position of the 

function switch during measurements.

•  Never connect unit to AC or DC powered circuits when the function 

switch is set to resistance, diode check or continuity ranges.

•  Always disconnect the power when performing resistance, diode or 

capacitance tests. Discharge capacitor before testing.

•  Disconnect the live/positive test lead (red) prior to disconnecting the 

common/negative test lead (black).

•  When 

 appears on the display, change both batteries to achieve 

more accurate readings.

•  Disconnect the test leads before removing the batteries or the fuse.
•  Do not operate the unit unless the case is completely closed.
•  When using the test probes always keep fingers behind the finger 

guards. Never touch the exposed probe tip.

•  Always inspect the instrument, test leads and other accessories for 

damage prior to use.

•  Use only UL recognized test leads (included with this meter).

Содержание DMR-4350

Страница 1: ...USER S MANUAL DIGITAL MULTIMETER DMR 4350 CIRCUIT TEST ELECTRONICS www circuittest com...

Страница 2: ...play 8 1 DC Voltage Measurement 9 2 AC Voltage Measurement 9 10 3 DC Current Measurement 10 11 a less than 326mA DC current b 326mA or more DC current 4 AC Current Measurement 11 13 a less than 326mA...

Страница 3: ...DC or 30VAC RMS as these volt ages pose a shock hazard Always consider circuits to be energized Never assume any equipment to be de energized Always start with power off Set the function switch to the...

Страница 4: ...in the Operating Instructions 500V MAX This symbol indicates that the terminal s so marked must not be con nected to a circuit point at which the voltage with respect to ground exceeds 500V AC DC Thi...

Страница 5: ...e test the following Voltage Current Resistance Continuity Diode Temperature LCD DISPLAY SYMBOL DEFINITIONS DISPLAY SYMBOL DEFINITION DISPLAY SYMBOL DEFINITION Diode A Amps Data Hold Range Hold AC Alt...

Страница 6: ...freeze and will appear on the LCD Changes in the input signal will not change the display 9 FUNCTION Switch Function Switch to select measurement mode 10 Test Lead Input Indicating LEDs Lighted LED in...

Страница 7: ...sounds if resistance is less than 20 Over range indication OL is displayed Operating Temp 5 to 40 C 41 to 104 F Storage Temp 10 to 50 C 14 to 122 F Relative Humidity 75 Operating Storage Power Source...

Страница 8: ...s 2 reading 8 digits AC CURRENT AC A 40 400HZ 326 A 3 26mA 32 6mA 326mA 20A 100nA 1 A 10 A 100 A 10mA 1 5 reading 5 digits 3 reading 5 digits RESISTANCE 326 3 26k 32 6k 326k 3 26M 32 6M 0 1 1 10 100 1...

Страница 9: ...button twice or press the HOLD button or RANGE button once ANALOG BARGRAPH DISPLAY Besides the digital readout this meter also indicates all the measurements on the bargraph at the bottom of the displ...

Страница 10: ...positive Read the displayed voltage If the minus sign appears it means the voltage is negative at the point being measured If OL appears on the display it indicates over range Immediately re move test...

Страница 11: ...ng for this function If you wish to measure with Manual range follow instructions described in Section 9 For manual ranging start at the highest range and work down a Less than 326mA DC Current Measur...

Страница 12: ...ircuit and connect the black lead to the negative side and the red lead to the positive side of the circuit so that the test leads are in series with the load to be measured Apply power to the circuit...

Страница 13: ...current If the numeral value in the display is too small change the function switch from mA to A for a more sensitive measurement range If OL appears on the display it indicates over range Immediatel...

Страница 14: ...POSITION OF THE FUNCTION SWITCH NOTE The meter will be Auto ranging for this function If you wish to measure with Manual range follow instructions described in Section 9 For manual ranging start at t...

Страница 15: ...O REMOVE ALL POWER FROM THE CIRCUIT BEING TESTED WHEN PERFORMING THE DIODE TEST DISCHARGE ANY CHARGED CAPACITORS Note If the diode is part of a circuit it is necessary to discon nect one end of the di...

Страница 16: ...e function switch to C or F depending on whether the temperature is to be measured in degrees Celsius or degrees Fahrenheit Plug the K type thermocouple in the TEMP jack NOTE The K type thermocouple s...

Страница 17: ...nd return to auto rang ing press and hold the Range button until disappears from the display 10 HOLD FUNCTION Use this function to hold a reading When this pushbutton is pressed the data being display...

Страница 18: ...FUSE REPLACEMENT WARNING DISCONNECT BOTH TEST LEADS FROM ANY SOURCE OF VOLTAGE BEFORE REMOVING THE BACK COVER DO NOT OPERATE THE METER UNTIL THE BACK COVER IS IN PLACE AND FASTENED SECURELY a 0 5 Amp...

Страница 19: ...open Remove the batteries Carefully lift the top of the case away from the bottom CAUTION Lift the top case carefully do not break the wires attached to the battery compartment Gently lift the battery...

Страница 20: ...Fast Ceramic 16A 500V Batteries 2 x AAA LIMITED WARRANTY Circuit Test Electronics warrants to the original purchaser that this product be free of defect in material or workmanship for a period of 2 y...

Отзывы: