THE LEADER IN OIL MIST TECHNOLOGY

  

77740201 REV 4 January 17, 2019 

Installation 

Install the Model “VM” on a wall or column in an upright position using the four mounting holes on the unit reservoir. The oil level gauge 
should be in full view, and the oil fill port, located on the top of the mist head, must be accessible. 

Connect the oil mist distribution system to the 1" NPTF oil mist outlet located on the right side of the mist head. Connect a clean, dry 
compressed air supply to the left side of the oil mist unit. For units furnished with the 

LubriMist

® 

integral air filter/regulator, maximum supply 

air pressure is 125 PSIG. If customer provided air controls are installed, they should be capable of varying and controlling the supply air 
pressure to the mist head from 10 to 50 PSIG. 

It is recommended that a mist pressure gauge, Part No. U-902-S (purchased separately), be installed in the oil mist header. The mist 
pressure gauge should be located so that it can be easily read and monitored as adjustments to the integral air filter/regulator are made 
during start-up. 

This LubriMist

®

 Oil Mist Generator has been designed and factory tested with LubriMist

®

 Synthetic Oil (LSO).  LSC recommends LSO for 

this oil mist generator in order to insure optimum performance. 

Electrical connections should be made by a qualified electrician. All conduit connections are 1/2" NPTF. See "Electrical"  for electric 
component  configuration  and  wiring  diagrams.  The  low-level  alarm  switch  can  be  used  for  local  or  remote  annunciation.  (Alarm 
annunciation is provided by the purchaser.) The air solenoid valve should be installed with a local user provided disconnect.  

Start-Up 

Prior to start-up, recheck all connections and insure that all fittings are tight and electrical connections are properly made. Insure that the 
oil mist distribution system, reclassifiers, and application point connections, vents and drains are properly installed. 

If a mist pressure gauge has been installed in the oil mist header, calculation of the system flow rate is not necessary for start-up. If a mist 
pressure gauge is not installed use Figure 2 to determine the total system flow rate. 

This flow rate is necessary to determine the proper regulated air pressure setting in Step No. 3 below:

   

DETERMINE SYSTEM FLOW RATE

 

 

BI SIZE 

 

TYPE 

 

PART NO. 

 

FLOW RATE 

QUANTITY 

INSTALLED 

 

TOTAL SCFM 



Mist 
Condensing 
Spray 

77-800-500 
77-700-151 
77-700-181 

0.03 
0.03 
0.03 

 
 

 
 



Mist 
Condensing 
Spray 

77-800-501 
77-700-152 
77-700-182 

0.09 
0.08 
0.06 

 
 

 
 



Mist 
Condensing 
Spray 

77-800-502 
77-700-153 
77-700-183 

0.18 
0.16 
0.09 

 
 

 
 

10 


Mist 
Condensing 
Spray 

77-800-503 
77-700-154 
77-700-184 

0.30 
0.26 
0.19 

 
 

 
 

15 
11 
12 

Mist 
Condensing 
Spray 

77-800-504 
77-700-155 
77-700-185 

0.45 
0.36 
0.30 

 
 

 
 

20 

 

Mist 
Condensing 
Spray 

77-800-505 

--- 
--- 

0.60 

--- 
--- 

 
 

 
 

FIG. 2 
 
 

System Total                         SCFM 

To Start the LubriMist

®

 Model "VM" 

1.  Remove the oil cap, located on top of the mist head, and fill the oil reservoir approximately 75% full, taking care not to exceed the 

"high" level mark on the oil sight gauge. Oil selection should be made based on lubrication and viscosity requirement dictated by the 
machinery components being serviced. DO NOT USE MOTOR OIL or any other oil that has viscosity improving additives. Replace the 
oil fill cap. 

2.  Turn on the air supply to the integral air filter/regulator.  For units equipped with an air solenoid valve, turn on the electrical power to 

the air solenoid valve.   

3.  Adjust the regulated air pressure: 

a.  If a mist pressure gauge has been installed in the oil mist header, adjust the integral air filter/regulator until the desired mist 

pressure reading is achieved. Mist pressure setting should be set at 20" H

2

O for "CONDENSING" and "SPRAY" type systems. 

 

b.  If a mist pressure gauge has not been installed, refer to the total SCFM flow rate determined in Figure 2. Using Figure 5, locate 

the proper flow curve for size unit installed. Knowing the SCFM requirement, draw a horizontal line from the SCFM requirement 
until it intersects the line for the correct mist head size. Drop vertically down and read the regulated air supply pressure. Adjust 
the integral air filter/ regulator (Item 7, Fig. 3) until the air pressure gauge (Item 6, Fig. 3) reads this setting. (Minimum regulated 
air pressure setting is 10 PSIG). 