background image

 

I.1.1 SEAL REMOVAL 
 

Step 1. 

Re-install the centering clips finger tight, ensuring the clip is toward the cartridge gland. 

 

   

Step 2. 

Loosen the gland bolts (5). 

 

Step 3. 

Tighten centering clip cap screws 1/8 turn (roughly 20 in-lbs. (2.26 Nm)). 

 

Step 4 

 Loosen all set screws in the locking ring. 

 

Note: 

If you are troubleshooting an  improperly centered gland, proceed to  Seal 
Installation (Section I.1.2), Step 5.  Otherwise, disregard this note. 

 

Step 5

Remove gland bolts (5) and washer (98). 

 

Step 6 

Grasp cartridge gland and slide mechanical seal cartridge assembly from power rotor (13) 
shaft.  Remove gland gasket from gland face. 

 

I.1.2 SEAL INSTALLATION 
 

Note:  Mechanical seal elastomers are Kalrez.  Lubricate the mechanical seal elastomers prior 
to installation with a clean silicone based lubricant that is process compatible. 

 

 

CAUTION 

 

When installing/repositioning the seal make sure the centering clips and socket head cap 
screws are engaged. If for any reason centering clips are loosened prior to installation, 
tighten cap screw finger tight then turn cap screw 1/8 turn (roughly 20 in-lbs. (2.26 Nm)).   

 

Step 1. 

Assure that all components are free of nicks and burrs. 

 
Step 2. 

Install gland gasket to gland face. 

 
Step 3. 

Make sure all screws  are engaged in the lock ring  but do not protrude into the ID 

bore. 

 
Step 4. 

Install pipe plugs (100) in the quenching ports. 

 
Step 5. 

Slide the completely assembled Chesterton 180 mechanical seal onto the shaft by 

pushing on the lock ring.   

 
Step 6. 

Install washers (98) and gland bolts (5). Tighten the gland bolts (5) evenly to 15 +   2 

ft-lbs. (20.3 +  2.7 Nm). 

 
Step 7. 

Place power rotor (13) in the middle of its .015 to .020 inch total axial movement.   

 

IMPORTANT:  All dog point set screws must be tightened FIRST. 
 
Step 8. 

Evenly hand tighten dog point set screws. Evenly hand tighten cup point set screws. 

 

Step 9. 

Retighten the six set screws (dog point first) to 55 + 5 in-lbs. (6.2 + .56 Nm). 

 

Step10. 

Loosen cap screws holding centering clips in place.  Remove centering clips and store 

away for later use. 

Содержание IMO C324AXFX-12005

Страница 1: ...FOR C324AXFX 250 12005 PUMP WARNING This Instruction Manual and General Instructions Manual SRM00046 should be read thoroughly prior to pump installation operation or maintenance of Pump SRM00110 Rev...

Страница 2: ...persons Safety instructions where electrical safety is involved are identified by Safety instructions which shall be considered for reasons of safe operation of the pump and or protection of the pump...

Страница 3: ...ational practices which may not be otherwise covered by this manual In applications where equipment furnished by Imo Pump is to become part of processing machinery these instructions should be thoroug...

Страница 4: ...manual record figure numbers that apply to replacement part s 4 From assembly drawing or parts list see Figure 4A 4B and Table 2 provide IDP number s and names for replacement part s 5 Give above info...

Страница 5: ...HEX CAP SCR 1 2 13 X 2 250 XX 0007 2 PP070AE PLUG 3 8 SHP 0008 1 S904ET 1X3 ROTOR HOUSING XX 0010 1 S904ET 1X4 ROTOR HOUSING XX 0011 2 S836BMX9 PIN STOP XX 0012 1 S838EJX3 SPACER 0013 1 DSC250HK ROTOR...

Страница 6: ...astened joint is achieved for each application the following procedure is mandatory assembly practice Step 1 Using a suitable torque wrench install the fasteners in the mating piece until the Nylok in...

Страница 7: ...ket head cap screws are engaged If for any reason centering clips are loosened prior to installation tighten cap screw finger tight then turn cap screw 1 8 turn roughly 20 in lbs 2 26 Nm Step 1 Assure...

Страница 8: ...using wrap the rotors with a sling to prevent accidental dropping and to assist in holding the rotors in mesh for easy removal Step 5 Remove inboard end cover bolts 2 and remove inboard end cover 17 a...

Страница 9: ...e end rotor housing 10 assuring that rotor housing end faces are fully seated against spacer 12 faces To assist in aligning housing bores install idler rotors 14 into idler bores Rotate rotor housings...

Страница 10: ...sing a parallel bridge measure and record distances Q and X on inboard end cover 17 Subtract Q from X and add 009 23 mm 60 of gasket 4 thickness to this number Set adjusting screws to this distance fr...

Страница 11: ...t 4 thickness to this number Make sure rotor housing 8 10 are seated against inboard housing adjusting screws Measure and record distance W from case 1 end flange to housing 10 end face If housing 10...

Страница 12: ...ent is not achieved Step 6 Install Chesterton 180 cartridge mechanical seal 27 per instruction in Mechanical Seal Section of this manual See Section I 1 2 K INSTALLATION ALIGNMENT AND TROUBLESHOOTING...

Страница 13: ...13...

Страница 14: ...14 Circor 1710 Airport Road PO Box 5020 Monroe NC USA 28111 5020 Tel 1 704 289 6511 Email cc circor com Web www circorpt com 2020 CIRCOR Pumps North America LLC all rights reserved...

Отзывы: