background image

Disassembly Procedures (Figures 3, 7, 8, 9) 

 

 

WARNING

 

 

 

When inspecting/servicing shaft seal and/or bearing, power rotor can be removed as a 
subassembly with these components installed. Remove four (4) bearing retainer plate 
bolts and retainer plate, and then remove power rotor sub-assembly.  If for any reason 
pump is disassembled further than this, it is possible idler rotor balance piston housings 
may fall off.  These idler rotor balance piston housings MUST be properly in place at 
reassembly.  If idler rotor balance piston housings are not properly installed on idler 
rotors, pump WILL experience catastrophic failure.

 

Figures listed are basic pump assembly figures.  For variations that may apply to your pump, see figure 16 
for seal installation variations. 
 
1. 

Close off suction and discharge piping to pump and disconnect piping. 

 
2. 

If applicable, remove tubing (071) and, if applicable, check valve (078). 

 
3. 

Remove inlet drain plugs and drain unit.  Remove pump from driver, coupling and mounting bracket.  
Remove coupling hub and key (031). 

 
4.   Remove inlet capscrews (004), inlet head (002) and gasket (009) or O-ring (070 or 075) as applicable. 
 
5.  

(Figures 3, 7 and 8)

 Remove thrust cage (029).  Remove oil balance tube (026) with O-rings (027) 

from either thrust cage (029) or rotor housing (024).  Remove O-rings (027) from oil balance tube (026). 

 
6. 

(Figures 3, 7 and 8)

 Remove idler balance piston housings (023) from idler rotors (021), and remove 

idler rotors (021) by unscrewing idlers from rotor housings (024). 

 
7. 

(Figures 9)

 Remove bolts (029 or 053) with lockwashers (030 or 052).  Remove thrust plate (026 or 

029) and spacers (023 or 051). Remove spacer (040 or 050) from case (001). 

 
8. 

(Figures 9)

 Remove idler rotors (021) from housing (024) bores by unscrewing idler rotors from 

threads of power rotor. 

 
9. 

Remove bolts (047 or 017) and bearing retainer (043 or 016). 

 
10.  Remove power rotor (044 or 063) assembly from case (001). 
 

NOTE: 

Removal of power rotor (044 or 063) will also remove Truarc rings (042), ball bearing (049), 
spacer (048 or 014), sleeve (037 or 038) if applicable and mechanical seal (025). 

 

NOTE: 

Balance piston furnished as part of power rotor (044 or 063) and is not serviced separately. 

 
11. Remove gasket from bore of inboard cover (046 or 008). 
 
12. Remove inboard cover capscrews (004) and inboard cover (046 or 008) from case (001). 
 

NOTE: 

Removal of inboard cover (046) may include removal of O-ring (028) and bushing (086).  
Bushing (086) is locked to inboard cover (046) with Loctite retaining compound and should not 
be removed unless replacement is necessary. 

 
13.  Remove gasket (009) from case (001). 
 

Содержание IMO A3D Series

Страница 1: ...S LIST FOR A3D SERIES PUMPS WARNING This Instruction Manual and General Instructions Manual SRM00046 should be read thoroughly prior to pump installation operation or maintenance Manual No SRM00038 Re...

Страница 2: ...Every effort is made to prepare text of manual so that engineering and design data is transformed into most easily understood wording Imo Pump in furnishing this equipment and this manual must presum...

Страница 3: ...rature Packing Z Borg Warner Type Q Viton Fitted Hi Temp Bearing 4th Letter Designator J Carbide Seal Seat Silicon T Carbide Seal Seat Tungsten X Special Material or Const 3rd Letter Designator C Circ...

Страница 4: ...ter Designator F 100 SSU Minimum 1st Letter Designator B 33 SSU Min 2500 SSU Max 1st Letter Designator H 33 SSU Min 15000 Max Minimum Liquid Temperature 0 F Maximum Liquid Temperature figure 1 1st Let...

Страница 5: ...ruarc Ring 2 074 Elbow 021 2 Idler Rotor 2 074 Nameplate 022 Oil Balance Tube External 075 O ring Figure 10 022 2 Balance Piston Housing 075 Plug 023 2 Idler Balance Piston Housing 2 075 Nipple 023 Sp...

Страница 6: ...chanical Seal and Ball Bearing Only Follow steps 8 9 10 and 11 DISASSEMBLY AND ASSEMBLY PROCEDURES MECHANICAL SEAL PUMPS WARNING To prevent personnel equipment injury power supply to pump driver must...

Страница 7: ...cage 029 Remove oil balance tube 026 with O rings 027 from either thrust cage 029 or rotor housing 024 Remove O rings 027 from oil balance tube 026 6 Figures 3 7 and 8 Remove idler balance piston hou...

Страница 8: ...Replace all worn or damaged parts Imo Pump Division recommends automatic replacement of O rings 027 028 and 038 gaskets 009 Dyna seal 007 ball bearing 049 or 015 and mechanical seal 025 when these par...

Страница 9: ...4 120 5 lb ft 47 38 2 lb ft 400 4 170 5 lb ft 47 38 2 lb ft 8 Assemble power rotor 044 or 063 as follows Figures 7 8 9 Install sleeve 038 on power rotor 044 or 063 shaft next to piston Figures 3 7 8 9...

Страница 10: ...embly 18 Install key 031 and coupling hub on power rotor 044 or 063 shaft DISASSEMBLY AND ASSEMBLY PROCEDURES PACKING PUMPS Disassembly Procedures Figures 4 5 and 6 NOTE Refer to pump assembly drawing...

Страница 11: ...rts are disturbed from their previously installed position Refer to pump assembly drawings Figures 8 9 and 10 and List of Material Table 3 during pump assembly Coat all parts with light lubricating oi...

Страница 12: ...rotor housing 024 idler rotor bores by engaging threads of idler rotors with threads of power rotor 019 or 063 and rotating idler rotors 021 while inserting them into rotor housing 024 15 Install idle...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ...Figure 7 A3D 218 250 275 312...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ...CIRCOR 1710 Airport Road PO Box 5020 Monroe NC USA 28111 5020 Tel 1 877 853 7867 Email cc circor com Web www circorpt com 2020 CIRCOR Pumps North America LLC All rights reserved...

Отзывы: