background image

 

3

A. GENERAL INSTRUCTIONS 

 

Instructions found herein cover disassembly, assembly and parts identification of 3E-143, 143J and 
162 pumps.

  

 

NOTE:   Individual contracts may have specific provisions that vary from this manual.  Should any 

questions arise which may not be answered by these instructions, refer to 

General 

Installation, Maintenance and Trouble Shooting Manual, SRM00046

 

provided with 

your order. For further detailed information and technical assistance please refer to Imo 
Pump, Technical/Customer Service Department, at (704) 289-6511.

 

 

This manual cannot possibly cover every situation connected with the inspection, and maintenance of 
equipment supplied. Every effort was made to prepare text of manual so that engineering and design data is 
transformed into most easily understood wording. Imo Pump must assume personnel assigned to operate 
and maintain supplied equipment and apply this instruction manual have sufficient technical knowledge and 
are experienced to apply sound safety and operational practices which may not be otherwise covered by 
this manual. 
 
In applications where equipment furnished by Imo Pump is to become part of processing machinery, these 
instructions should be thoroughly reviewed to ensure proper fit of said equipment into overall plant 
operational procedures. 
 

 

 

WARNING

 

 

If installation, operation and maintenance instructions are not correctly and strictly followed and 
observed, injury to personnel or serious damage to pump could result.  Imo Pump cannot accept 
responsibility for unsatisfactory performance or damage resulting from failure to comply with instructions. 

 

B. INTRODUCTION 

 

Instruction manual covers 3E-143, 143J and 162 series pumps.  Specific models covered by this manual 
are identified in Table 2.  Model of each particular pump is identified on pump end cover.  Refer to Figure 1 
for definition of model designator.  Refer to assembly drawing corresponding to your pump model, Figures 3 
through 11 as you use this instruction manual. 
 

C. DESCRIPTION OF EQUIPMENT 

3E-143, 143J and 162 series pumps are positive displacement, rotary screw pumps consisting of precision 
bored housings which enclose a driven screw (power rotor) and intermeshing following screws (idler rotors). 
These screws when rotating form a succession of closures or cavities. As they rotate, fluid is moved axially 
from inlet port to outlet port in a continuous, uniform flow with minimum fluid pulsation and pump noise.  
 

D. PUMP MODEL IDENTIFICATION 
 

This service manual covers Imo Series 3E-143, 143J and 162 pumps. The model of each pump is identified 
on pump nameplate. Refer to figure 1 and table 1 for instructional keys when using this manual. 

Содержание IMO 143

Страница 1: ...ND 162 WARNING This Special Instruction Manual and General Installation Operation Maintenance and Troubleshooting Manual Three Screw and CIG Pumps SRM00046 should be read thoroughly prior to pump inst...

Страница 2: ...ty instructions where electrical safety is involved are identified by Safety instructions which shall be considered for reasons of safe operation of the pump and or protection of the pump itself are m...

Страница 3: ...roper fit of said equipment into overall plant operational procedures WARNING If installation operation and maintenance instructions are not correctly and strictly followed and observed injury to pers...

Страница 4: ...required Imo sales and service representatives are listed herein and in General Installation Maintenance and Trouble Shooting Manual SRM00046 F OPERATION F 1 LIQUID LIMITATIONS CAUTION ATTENTION Never...

Страница 5: ...are expected to be less than 70 dBA G PARTS LIST Table 1 List of Material Item Qty Part Description Item Qty Part Description 1 1 Case Housing 16 1 1 Seal 2 2 1 Outboard End cover 26 1 1 Inboard Cove...

Страница 6: ...NTS NOTE Part number identifiers contained within parenthesis such as 3 refer to circled numbers shown on assembly drawings Figures 3 through 11 DANGER De energize driver before starting with any main...

Страница 7: ...de bearing retaining ring 15 from groove of power rotor 7 Put power rotor 7 on a press with bottom of seal seat adapter 92 on plate of press Press power rotor 7 through bearing 11 and seal seat adapte...

Страница 8: ...inboard cover 4 and assemble inboard cover 4 to case 1 with hex bolts 27 Skip to step 9 5 Assembly Power rotor as follows a Coat power rotor 7 seal area with lubricating fluid and install seal rotatin...

Страница 9: ...hub on power rotor 7 Install pump on driver and check alignment as described in Manual Number SRM 00046 General Installation Operation Maintenance and Troubleshooting Manual Prime pump to expel air pr...

Страница 10: ...1 26 13 4 7 8 8 2 USE LOCTITE GASKET ELIMINATOR 504 ASSEMBLE PUMP SO THAT END OF IDLER WITH ROOT TAPER IS AT INLET END OF PUMP INLET OUTLET TORQUE TO 170 u 10 LB IN TORQUE TO 170 u 10 LB IN FIGURE 3 I...

Страница 11: ...F IDLER WITH ROOT TAPER IS AT INLET END OF PUMP TORQUE TO 170 u 10 LB IN TORQUE TO 170 u 10 LB IN USE LOCTITE GASKET ELIMINATOR 504 NOTES 1 DRAIN HOLE IN COVER 4 TO BE ASSEMBLED IN THE DOWN POSITION 7...

Страница 12: ...MBLE PUMP SO THAT END OF IDLER WITH ROOT TAPER IS AT INLET END OF PUMP INLET OUTLET TORQUE TO 170 u 10 LB IN TORQUE TO 170 u 10 LB IN TORQUE TO 40 u 2 LB IN AUXILIARY SEAL DRAIN NOTES 1 DRAIN HOLE IN...

Страница 13: ...OR 504 ASSEMBLE PUMP SO THAT END OF IDLER WITH ROOT TAPER IS AT INLET END OF PUMP INLET OUTLET TORQUE TO 170 u 10 LB IN TORQUE TO 170 u 10 LB IN TORQUE TO 40 u 2 LB IN NOTES 1 DRAIN HOLE IN COVER IDP...

Страница 14: ...ER IS AT INLET END OF PUMP TORQUE TO 170 u 10 LB IN TORQUE TO 170 u 10 LB IN TORQUE TO 40 u 2 LB IN USE LOCTITE GASKET ELIMINATOR 504 NOTES 1 DRAIN HOLE IN COVER 4 TO BE ASSEMBLED IN THE DOWN POSITION...

Страница 15: ...OT TAPER IS AT INLET END OF PUMP TORQUE TO 170 u 10 LB IN TORQUE TO 170 u 10 LB IN TORQUE TO 40 u 2 LB IN USE LOCTITE GASKET ELIMINATOR 504 NOTES 1 DRAIN HOLE IN COVER 4 TO BE ASSEMBLED IN THE DOWN PO...

Страница 16: ...u 10 LB IN TORQUE TO 75 u 5 LB IN INLET OUTLET ASSEMBLE PUMP SO THAT END OF IDLERS WITH ROOT TAPER IS AT INLET END OF PUMP NOTES 1 DRAIN HOLE IN COVER IDP 4 TO BE ASSEMBLED IN THE DOWN POSITION 1 8 27...

Страница 17: ...TO 170 u 10 LB IN TORQUE TO 75 u 5 LB IN INLET OUTLET ASSEMBLE PUMP SO THAT END OF IDLER WITH ROOT TAPER IS AT INLET END OF PUMP NOTES 1 DRAIN HOLE IN COVER IDP 4 TO BE ASSEMBLED IN THE DOWN POSITION...

Страница 18: ...TORQUE TO 35 2 LB IN TORQUE TO 131 10 LB IN OUTLET INLET NOTES 1 DRAIN HOLE IN COVER IDP 4 92 TO BE ASSEMBLED IN THE DOWN POSITION SEE NOTE 1 11 15 ASSEMBLE PUMP SO THAT END OF IDLER WITH ROOT TAPER...

Страница 19: ...CIRCOR 1710 Airport Road PO Box 5020 Monroe NC USA 28111 5020 Tel 1 877 853 7867 Email cc circor com Web www circorpt com 2020 CIRCOR Pumps North America LLC All rights reserved HOW NOW...

Отзывы: