A
A
SECTION A-A
92
4
12
15
11
13
6
27
26
93
16
1
7
8
8
2
3
5
TORQUE TO
170
u
10 LB IN
TORQUE TO
170
u
10 LB IN
TORQUE TO
75
u
5 LB IN
INLET
OUTLET
ASSEMBLE PUMP SO THAT END OF
IDLERS WITH ROOT TAPER IS AT
INLET END OF PUMP
NOTES:
1.DRAIN HOLE IN COVER IDP #4 TO BE ASSEMBLED
IN THE DOWN POSITION.
1/8-27 NPT
1/4-20 UNC-2B
1/4 FULL THREAD
AUXILIARY SEAL DRAIN
FIGURE 9 - IRON CASED D3EJ(N)C - C-FACE MOUNTING