Disassembly, Inspection & Reassembly
64
216 Series
Twin-Screw Pump -
Installation, Operation, and Maintenance Manual
Fasteners
WARNING:
Risk of serious personal injury or property damage. Fasteners such as bolts and nuts are
critical to the safe and reliable operation of the product. Ensure appropriate use of fasteners
during installation or reassembly of the unit.
•
Use fasteners of the proper size and material only.
•
Replace all damaged or corroded fasteners.
•
Ensure that all fasteners are properly tightened and that there are no missing fasteners.
Additional parts
Inspect and either repair or replace all other parts, if inspection indicates continued use would
be harmful to satisfactory and safe pump operation. Inspection must include these items:
•
Gear housing (406) and bearing housings (401) (407)
•
Oil seals (704) (721)
•
Bearing locknut (110)
•
Coupling key (133)
•
All nuts, bolts, dowels and screws