5.2 ELECTRICAL WIRING CONSIDERATIONS
Before starting with the wiring connection of the charging
station, you must take into consideration this section.
1. Charging point power supply
The charging point does not include elements for electrical protection.
The power supply line which comes from the distribution board to the charging point, must
meet the electrical safety standards, according to your country regulations. The minimum
safety required protections are as follows:
-
RCD: Type A. I
ΔN
=0.03A.
-
MCB: Its gauge must be chosen depending on the maximum output current of the
charging point.
NOTE: For further information, please refer to the TECHNICAL DATA section.
2. Power supply - Line dimensioning
The dimensioning of the charging station power supply line must be checked by a qualified
electrician. Note that various factors such as the cable length between the distribution
board and the unit, its maximum output current or ambient temperature may have influence
of the selected cable.
So, it is important to select the appropriate cable cross-section in agreement with the local
regulations and the power supply cable type that it is used.
3. Charging point maximum output current
If the installed charging point power supply is less than the maximum output current of the
charge point, an adjustment to a lower nominal current must be performed using the on-
board rotate dipswitch.
NOTE: Please refer to the CURRENT LIMIT SELECTOR section in order to know how