3
Host Interface Setting
FuzzyScan Scan Engine is designed to support RS232 Serial, USB HID and USB
COM Port Emulation interfaces. Please choose RS232 or USB interface cable
before connecting the Scan Engine Evaluation Kit and host device.
The default host interface of Evaluation Kit is USB COM Port Emulation. But for
easy evaluation purpose, the host interface of Evaluation Kit has been preset to
USB HID for your convenience. Please refer to following table and illustration to
arrange the proper dip switch setting to get your desired host interface.
Dip Switch
RS232
USB
1
ON
OFF
2
ON
OFF
3
OFF
ON
4
OFF
ON
Please scan the corresponding Host Interface Quick Set barcode command to
complete the host interface setting after you finish the dip switch setting.
If the USB COM Port Emulation interface is selected, you have to install the USB COM Port
Emulation driver in your host system before using the Scan Engine. You can download the
driver from the website
www.cino.com.tw
.
RS-232 Serial
USB