User Menu Parameters
HB SERIES
50
%
T
H
U
D
37.7
10
%
T
H
U
D
hhı
-10
%
T
H
U
D
hlo
0,8
%
T
H
U
D
-2.0
%
T
H
U
D
Hold T + H together for 3 seconds to enter menu
-Use T /H buttons to choose parameter.
-Use U/D buttons to change parameter values.
-Hold T + H together for 3 seconds to save changes.
hhi: high humidity alarm.
Started :
set value +10
Delay time:
20 minutes
Notification:
Alr 5
Voice alarm :
continuous
hlo: low humidity alarm.
Started :
set value -10
Delay time:
20 minutes
Notification:
Alr 6
Voice alarm : intermittently
(f)thi: high temperature alarm.
Started :
set value + 0,8
Delay time:
2 minutes
Notification:
Alr 1/3
Voice alarm :
continuous
(f)tlo: low temperature alarm.
Started :
set value - 2.0
Delay time:
30 minutes
Notification:
Alr 2/4
Voice alarm : intermittently
tco: temperature calibration value.
CAUTION!
tCo is a critical parameter . Changing this can
results in chick looses. Plsease use qualified and
calibrated
glass
or
electronic
thermometers
for
calibrationpurpose. Check temperature values regularly.
hco: humidity calibration value.
CAUTION!
hCo is a critical parameter. Changing this can
results in chick looses. Please use qualified and
calibrated
glass
or
electronic
thermometers
for
calibration purpose. Check humidity values regularly.
(f)thi
(f)tlo
th
%
T
H
U
D
uS2
18
%
T
H
U
D
(f)rtl
28
%
T
H
U
D
(f)rth
10
%
T
H
U
D
rhl
85
T
H
U
D
off
%
T
H
U
D
rhh
rAt
off
%
T
H
U
D
rAh
0.0
%
T
H
U
D
hco
0.0
%
T
H
U
D
(f)tco
US2: USB connected device
no : no connected device
th : second sensor connected ( room/calibration)
ıot: iot module connected
Notification: Alr 15 (usb connection error)
below parameters active if Us2 is selected “th”
(f)rtl: second sensor low temperature alarm.
Started : below
18 C / 65 F
Delay time:
no
Notification:
Alr 10
Voice alarm : intermittently
(f)rth: second sensor high temperature alarm.
Started : over
28 C / 83 F
Delay time:
no
Notification:
Alr 9
Voice alarm : intermittently
rhl: second sensor low humidity alarm.
Started : below
10 RH
Delay time:
no
Notification:
Alr 14
Voice alarm : intermittently
rhh: second sensor high humidity alarm.
Started : over 85 RH
Delay time:
no
Notification:
Alr 13
Voice alarm : intermittently
rAt: second sensor temperature alarm activation.
On: alarms activated
Off: alarms deactivated
rAt: second sensor humidity alarm activation.
On: alarms activated
Off: alarms deactivated