background image

8  Technical specification 

 
 
Machine is of Class I construction. Enclosure to IP30. 
Model - 230 V ~ 50 Hz., fitted with supply cord type H05VV-F, 3 x 1.0mm² (10A), and plug. 
Model - 110 V ~ 50 Hz., fitted with supply cord type H05VV-F, 3 x 2.5mm² (25A), and plug. 

 

Model 

X46 

Brush motor 

190 

Vacuum motor 

2 x 750 

Brush speed 

rpm 

290 

Brush diameter 

cm 

15 

Working width 

cm 

46 

Length 

cm 

89 

Height 

cm 

23 

Weight 

kg 

44 

Sound pressure level   (

see note 1

dB(A) 

79 

Handle vibration    (

see note 2)

 

m/s² 

<

 2.5 

Supply cord length 

15 

 
1 - Sound pressure level measured at a distance of 1 metre from machine and 1,6 metres above floor. 

Measurements recorded using a hand held meter. For prolonged operation the wearing of ear defenders is 
recommended. 

2 - Handle vibration does not exceed 2,5 m/s², when operating on any surface. 

Measurements recorded by an independent test laboratory. 

 
 
 
 
 
 

9  Accessories 

 

Item 

Qty 

Part No. 

Application 

Nylon brush set  

05-4096-0000 

Regular daily maintenance

 

Tynex brush set 

05-4097-0000 

 

Periodic deep cleaning   (

see note1

)

 

Disposable paper bags (10 pack) 

02-4372-0000 

 

Regular dust collection

 

‘Escaclean’ degreasant (4 x 5litre) 

02-4404-0000 

Degreasing and stain removal

 

 

1 - CAUTION

 - 

Tynex brushes

 are very aggressive, and only suitable for occasional use on aluminium escalators 

only. 

Do not use

 on escalators with a coated surface as damage may result. 

IMPORTANT 

: Genuine accessories are only available from authorised Service Agents or Truvox Customer 

Service Dept. 

Содержание X46

Страница 1: ...ator and Travelator cleaner http www truvox com Products Escalators_and_Sweepers Cimex_X46 CAUTION READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03 7845 0000 Iss 1 07 04http www truvox com Products Escalators_and_Sweepers Cimex_X46 ...

Страница 2: ...2 Fig 1 Fig 2 ...

Страница 3: ...ring for use 4 2 1 Fitting the brushes 4 2 2 Electrical connection 4 3 Controls 5 4 Operation 5 4 1 Cleaning the escalator 56 4 2 Stain and spot removal 5 4 3 Dust bag replacement 5 5 Storage 5 6 Maintenance 5 7 After sales service 5 8 Technical specification 6 9 Accessories 6 10 Fault diagnosis 7 11 Guarantee 7 12 Declaration of conformity 8 ...

Страница 4: ...eport any problems Keep hands and feet well clear of rotating brushes Wear suitable footwear to avoid slipping Wear suitable clothing to keep dry and warm Do not smoke when using the machine CAUTION This machine is for dry use only and should not be used or stored outdoors in wet conditions 1 3 Transporting the machine CAUTION THIS MACHINE IS HEAVY Do not attempt to lift the machine without assist...

Страница 5: ...he machine until the bag is released from the vacuum tubes and carefully remove the bag for disposal Insert new bag pushing the rubber seals firmly over the tube ends until the cardboard collar is flat against the machine wall Fig 2 Close the top cover and locking pins The dust bag should be regularly replaced and the hoses checked for blockages If a bag bursts ensure that the filter is removed an...

Страница 6: ... a hand held meter For prolonged operation the wearing of ear defenders is recommended 2 Handle vibration does not exceed 2 5 m s when operating on any surface Measurements recorded by an independent test laboratory 9 Accessories Item Qty Part No Application Nylon brush set 2 05 4096 0000 Regular daily maintenance Tynex brush set 2 05 4097 0000 Periodic deep cleaning see note1 Disposable paper bag...

Страница 7: ... to the following conditions CONDITIONS 1 Claims made under the terms of the guarantee must be supported by the original invoice bill of sale issued at the time of sale or the machine Serial No 2 For claims under this guarantee contact the supplier from whom you purchased the product who will arrange the appropriate action Do not initially return the product as this could result in transit damage ...

Страница 8: ...Type Cimex Model X46 Serial Number Year of Construction 2004 has been manufactured using the following transposed harmonized European Standards and technical specifications BS EN 60335 1 and BS EN 60335 2 67 and is in conformity with EC Directives 98 37 EC 73 23 EEC and 89 336 EEC and all amendments Signed in SOUTHAMPTON England on the 30th day of July 2004 Signature Name M R Eneas Position New Pr...

Страница 9: ...9 ...

Страница 10: ...10 ...

Страница 11: ......

Страница 12: ...Truvox International Limited Third Avenue Millbrook Southampton Hampshire SO15 0LE England Tel 44 0 23 8070 2200 Fax 44 0 23 8070 5001 e mail truvox truvox com Web www truvox com ...

Отзывы: