P25. SELF-CLEANING FILTER FAUCET
(for the version where foreseen)
c
a
P25
It is placed in the lower part of the filter body (P7)
and connects it, through the pipeline (T6), to the
tank.
a - Open, filter cleaning
The mixture coming from the pump (P4) passes
through the filter (P7) removing residual product
that can cause the obstruction of the filter.
c - Closed, treatment
00215
P11
T5
P9
T4
00970
P9.
MANUAL DISTRIBUTOR WITH 2 LEVER-OPERATED TAPS
It connects the feeding pipe (T4) to the distribution
piping (T5). It remote-controls the closing and
opening of the pulverising. The mount bracket,
supplied with the machine, must be secured to the
tractor within the driver’s reach. When the machi-
ne is not hitched to the tractor, it must be placed
on the forward part of the sprayer’s frame.
Each tap permits the spraying from a single side
of the head: to the right and to the left respectively.
They are
open
when the levers are set in the
vertical
position.
They are
closed
when the levers are
horizon-
tal
.
00216
E9
E10
P11
T5
T4
®
+
-
ON
Remote Control
H O
2
ON
OFF
OFF
Pump
E9.
ELECTRICAL DISTRIBUTOR WITH TWO SOLENOID VALVES
(for the version where foreseen)
It is connected with the feeding pipe (T4), the
distribution pipes (T5) and the electrical unit
(E10), which is fastened on the tractor. The
solenoid valves open and close themselves,
according with the action carried out on the
electrical control unit switches.
In the E.P.A. versions, the controls of the cross
section solenoid valves are situated on the
electronic control unit (see specific manual).
Plus 42 - 45 - 50 - 55
09-2008
46
10.5.2 - End of seasonal cycle
•
L'operatore deve:
a
. Take the utmost care in carrying out the operations envisaged at the end of the daily treatments:
the cleaning of the hydraulic circuit
and the main tank
must be done at least twice. Check that no
product residues are left in any part of the circuit.
b.
Execute the necessary maintenance and lubrication operations (see paragraph 13.10), then let
the atomizer operate for some minutes.
THE PUMP MUST NEVER RUN DRY.
c
. Completely drain the hydraulic circuit, paying a special attention to the centrifugal pump; in order
to completely drain the pump, remove the draining plug, which is mounted on the pump itself.
00305
Avoid using anti-freeze solutions.
d
. Check the proper operation of all parts and of the machine structure. In case of faults being
detected, request the intervention of one of our service points.
e
. Keep the machine in a well ventilated place, sheltered from rain, icing and direct sun rays.
The use of detergent products for the cleaning operations is allowed only in the
observance of the regulations in force. For these, the operator must gather the
relevant information from the specifically appointed bodies ruling on this subject.