SERVICE MANUAL
TRANSTIG 300 AC/DC
June 30, 2008
12-1
SECTION 12:
POWER SOURCE ERROR CODES
Description
Possible Cause
Remedy
Remarks
A The Welding Power
Source’s duty cycle
has been exceeded.
A Let Power Source
cool down then
keep within its
duty cycle.
B Fan ceases
to operate.
B Have an accredited
Cigweld Service
Provider investigate.
C Air flow is restricted
by vents being
blocked.
C Unblock vents then
let Power Source
cool down.
A The Welding Power
Source’s duty cycle
has been exceeded.
A Let Power Source
cool down then
keep within its
duty cycle.
B Fan ceases
to operate.
B Have an accredited
Cigweld Service
Provider investigate
C Air flow is restricted
by vents being
blocked.
C Unblock vents then
let Power Source
cool down.
A Primary current is
too high because
welding arc is
too long.
A Reduce length of
welding arc.
B Mains supply
voltage is more
than 10% below
nominal voltage .
B Have an accredited
Cigweld Service
Provider or a
qualified electrician
check for low Mains
voltage.
E04 error code
displayed
Output voltage
exceeds the
secondary voltage
specification.
3 E03 error code
displayed
Primary (input)
current too high.
Weld current
ceases. Buzzer
sounds constantly.
Switch machine OFF
then ON to reset
E03 error.
4
TIG torch cable
and/or work lead
are too long or
leads are coiled.
Reduce the length
of the TIG torch
cable and/or work
lead or un-coiled
leads.
Weld current
ceases. Buzzer
sounds constantly.
Switch machine OFF
then ON to reset
E04 error.
1 E01 error code
displayed
Temperature sensor
TH1 (protects
IGBTs) is greater
than 80ºC for about
1 second.
Weld current
ceases. Buzzer
sounds constantly.
Fan operates at
max speed.
E01 resets when
TH1 decreases to
70ºC for about
30 seconds.
2 E02 error code
displayed
Temperature sensor
TH2 (protects
secondary diodes)
is greater than 80ºC
for about 1 second.
Weld current
ceases. Buzzer
sounds constantly.
Fan operates at
max speed.
E02 resets when
TH2 decreases to
70ºC for about
30 seconds.
Table 12-1 Power Source Error Codes
Содержание TRANSTIG 300 AC/DC
Страница 8: ......
Страница 20: ...TRANSTIG 300 AC DC SERVICE MANUAL 2 6 June 30 2008 THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 34: ...TRANSTIG 300 AC DC SERVICE MANUAL 5 2 June 30 2008 NOTES...
Страница 56: ...TRANSTIG 300 AC DC SERVICE MANUAL 11 2 June 30 2008 NOTES...
Страница 78: ...THIS PAGE LEFT INTENTIONALLY BLANK TRANSTIG 300 AC DC SERVICE MANUAL 13 18 June 30 2008...
Страница 125: ...THIS PAGE LEFT INTENTIONALLY BLANK TRANSTIG 300 AC DC SERVICE MANUAL June 30 2008 A 7...