![CIGWELD MPM 20/600 I-PS Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/cigweld/mpm-20-600-i-ps/mpm-20-600-i-ps_generating-set_2607026010.webp)
4.1 STARTING ENGINE
^ Check that engines fuel tank has been filled with diesel and the sump has been filled with
lubricating oil as specified in the Engine Manual.
^ Position the ignition key on the first step for preliminary heating then start the engine by
moving key completely clockwise.
^ After starting the engine, allow it to warm up by waiting 5 minutes before loading the
Engine Driven Welder.
^ Do not move the throttle control lever.
5.1 USE OF ENGINE DRIVEN WELDER AS A WELDER
^ Insert welding cable plugs into relevant sockets.
^ Set the current/voltage control knob on the front panel to the desired value on the
Engine Driven Welder. Take care that the REMOTE CONTROL switch is in 0 (OFF)
position.
^ Set the Arc Force control.
^ Remote current control can be achieved by using a remote control device.
^ When operating with remote control switch the remote switch control to position I
(ON) and connect the cable of the remote control unit to the 14 pin remote control
socket.
^ Connected the Electrode Lead to the positive terminal and the work lead to the
negative terminal.
Note: Stick electrodes are generally connected to the positive terminal but if in doubt
consult the electrode manufactures literature.