TRANSMIG 2RT
INSTALLATION/SETUP
INSTALLATION/SETUP 3-6
Manual 0-5196
CONTINUATION OF 250I POWER SOURCE CONTROLS
1. VRD Indicator
ON
OFF
WARNING
When the red VRD indicator is on and welding
is being performed, the presence of dangerous
voltage may be present at the electrode.
2. Power Indicator
The green power indicator will be illuminated when the
welder is turned on and indicates the presence of power.
3. Fault Indicator
The yellow fault indicator will be illuminated when any
of the faults are detected. ALL Faults will illuminate the
indicator
4. Weld Process Selection Button
LIFT TIG
WARNING
When the Power light is lit, the machine is
connected to the Mains supply voltage and
the internal electrical components are at Mains
voltage potential.
5. 2T - 4T Trigger Latch Button
6. Advanced Features Button
Gas Purge.
7. Left Knob: Amperage Control (Wirespeed)
Left Knob
8. Right Knob: Multifunction Control - MIG Voltage /
MIG Voltage Control
Right Knob
Push For Inductance
Arc Control
9. Left Digital Display
MIG Mode
This digital meter is used to display the pre-set (preview)
Wirefeed Speed in Metres Per Minute (MPM) in MIG mode
and actual welding amperage of the power source when