Startup the Cabinet

Close both doors.

Tap the screen to 

boot up the cabinet.

Enter Provisioning Key

End-points

Ports

IP Address

Provisioning Key

The cabinet will show you if the 

necessary network configurations 

have been made. If not, you will be 

unable to progress to the next step.  

Enter the provisioning key. 

A secure connection will be made 

between the cabinet and the 

customer’s software account.

Congratulations on completing the cabinet installation.

Thank you for being Torus partner, connect with us here:

torus-technology.com

[email protected]

linkedin.com/company/torus-technology

TORUS 

Installation Guide          

9

Содержание Torus 100

Страница 1: ...Installation Guide For assistance please email the manufacturer at support torus technology com Diagram above is shown with optional reader attached...

Страница 2: ...ner of all Torus and CIC trademarks reproduced in this document Other products brands trademarks referenced are not the property of CIC Technology POWER Cabinet is an electronic device It can be power...

Страница 3: ...are not supplied with the Torus cabinet Each fastener must hold at least 50lbs 20kgs and be appropriate for the wall substrate Mounting holes Fasteners 10mm 15mm Tools Required Power Spirit Level wit...

Страница 4: ...ncludes an additional strap to support the weight of the keypanel has 2 ribbon cables that connect to the Control Unit Accessories Box Accessories Override Key Backup Battery 12V 7AH Screws Washers 4...

Страница 5: ...that are run through the wall can enter the cavity behind the bracket at any point The mounting bracket is connected but not secured to the back of the cabinet Gently and carefully tilt the cabinet fo...

Страница 6: ...Use the screws and washers provided to secure the cabinet to the bracket Lift the cabinet onto the mounting bracket There are two pins at the top of the bracket that will locate into keyhole slots in...

Страница 7: ...ure the cabinet to the bracket using the screws and washers provided Access is limited around the top left screw so you will need to use the opended spanner wrench With the keypanel lowered check that...

Страница 8: ...ol unit KSP Ribbon Cable s These ports are interchangeable Torus 100 will have 2 cables Power cable Green Phoenix connector Ground This may be on the other side Ethernet Door Solenoid Door Sensor If y...

Страница 9: ...ave been made If not you will be unable to progress to the next step Enter the provisioning key A secure connection will be made between the cabinet and the customer s software account Congratulations...

Страница 10: ...control unit Use the override key to open the right hand door If the cabinet is already in a powered on state make sure you gracefully shut it down rst 1 Login as a cabinet admin 2 Tap settings 3 Tap...

Страница 11: ...485 The cabinet is capable of accepting inputs from Wiegand or OSDP devices Every reader is di erent so follow the manufacturer s instructions and connect it to the appropriate point on the control un...

Отзывы: