CONTROL UNITS
HEE 1-PH BOX (for Heliotherme or destratifier units fitted with HEE 1-PHASE motors)
Thank you for purchasing the "HEE 1-PHASE BOX" electronic control solution for
HELIOTHERME or DESTRATIFIER units fitted with HEE
1-PHASE motors. Up to 6 HELIOTHERME or 6 DESTRATIFIER units
or 3 HELIO 3 DESTRATIFIER units can be controlled using a single box.
This box allows the following:
•
Proportional variation of the supply air speed of the HEE 1-phase fan motor assembly (0-10V FMA)
according to the heating requirements of your building.
Heat or cool as precisely as possible in accordance with your needs.
• Supply water to one or more heat exchangers according to your building's heat requirements (available with the optional valve kit).
Control your supply air temperature to improve comfort levels and maintain the range of the air streams.
• Choose between fresh air only or mix with frost protection via the servomotor to be installed on the 2-channel mixing box with
built-in filter (available with the fresh air kit damper serv frost protection thermostat kit) or 100% recirculated air.
Adjust the fresh air rates in your building to meet current requirements or based on room occupancy levels (built-
in timer).
•
The internal timer can be configured on a weekly basis using 3 operating modes (Comfort, Eco, Frost protection), allowing
you to make environmentally-sound use of your air heaters.
The heating requirements of your building will depend on its occupancy level.
•
Centralised management of the HELIOTHERME units via the master controller allowing up to 10 HEE 1-PHASE BOX slave
units to be controlled (one HEE BOX master or slave unit controls 6 HELIOTHERME units or 3 HELIOTHERME units + 3
TPL).
The display shows the operating status of each individual HELIOTHERME unit (fresh air or return air, motor fault,
risk of frost, etc.)
•
All of the protective devices necessary to connect 6 units (heliotherme or TPL) as well as 6 valve kits.
Plug & Play solution
•
A remote on/off control is available as well as a two separate fault summaries. Possibility to communicate via ModBus, JBUS
or Bacnet IP.
Networked solution
Refer to the instruction manual supplied in the packaging of your HEE 1-PH BOX for further information
or contact your CIAT
agent.
3-speed HEE THERMOSTAT
• Functions
The HEE control includes a temperature selector (range from 10°C to 30°C) that maintains the room temperature at the selected
value.
• FAN operation
The user can use the fan speed selector button to set the fan's operating mode to manual or automatic.
In manual mode
, three types of speed can be selected (low, mid, high) depending on the requirements or energy saving
mode. This energy saving mode is particularly useful for air conditioning in rooms at night or rooms left unoccupied for long
periods.
In automatic mode
, the fan speeds are controlled by a microprocessor housed in the control unit, according to the temperature
selected. (see table below. (3 speeds possible depending on the heliotherme model)
Shunt 6
Shunt 7
Shunt 8
LOW
MID
HIGH
Heliotherm model
Heating
Cooling
Closed
Closed
Closed
→
2 V
6 V
10 V
H4300 / H4450
H4500 / H4630
Closed
Closed
Open
→
2 V
4 V
6 V
-
-
Closed
Open
Closed
→
6 V
8 V
10 V
-
-
Closed
Open
Open
→
2 V
3 V
4 V
-
H4400 / H4450
Open
Closed
Closed
→
8 V
9 V
10 V
-
-
Open
Closed
Open
→
5 V
6 V
7 V
H4400 / H4630
-
Open
Open
Closed
→
4 V
6 V
8 V
H4500
H4300
Open
Open
Open
→
3 V
6 V
9 V
H4350
H4350
H4000 HELIOTHERME
EN-16