background image

5 - SERVICING AND MAINTENANCE

The unit must be serviced periodically between the 

heating and cooling seasons. 

In particular, components prone to clogging (filter, 

condensate drain pan, coil, etc.) must be checked.

Disconnect  the  electrical  and  hydraulic 

supplies to the unit before carrying out any 

work  and  wait  at  least  20  mins  before 

working on or near the heating elements.

For your safety, wear protective gloves to 

prevent the risk of burns from hot pipes.

5.1 - 

Air filter

The filter is crucial to the correct operation of the unit. 

Without it, the heat exchange coil would become 

clogged,  the  performance  would  drop  and  the  unit's 

sound level and electrical consumption would increase.
The 

COMFORT LINE

TM

 is equipped as standard with 

the G3 or Epure filter. We recommend replacing it 

annually. If maintenance is carried out more frequently, 

dust can be removed from the filter by running a vacuum 

attachment in the opposite direction to the flow of air. 

The above recommendations are for information only. 

CIAT

  recommends  regular  inspections  of  the  filter's 

appearance in order to define the frequency with which 

it should be replaced, which varies depending on the 

premises and the operating conditions.

The unit may be supplied without a filter at the customer's 

request. 

The  customer  must  ensure  at  least  G3 

upstream filtration. Failure to do so will lead to loss 

of the motor warranty cover.

For LI/LY assembly version, the unit will be supplied with 

a compulsory G3 or Epure filter.

The filter should never be cleaned using water or 

detergent products, which could cause the spread of 

bacteria.

 

Accessing the filter (Fig.13), I, Y, H, U models: 

 

-

Option 1

 -

Mark the 2 screws on the filter bracket runner (a).

 - Undo the screws (b).

 -

Guide the filter downwards into its runner (c).

 -

Release the filter from its housing. 

 -

Once the new filter has been fitted, slide it against 

the rod, hold it securely and place the bracket 

runner back in position.

 - Tighten the 4 screws (a and b).

 

-

Option 2

 -

Remove the filter access panel using the 4 screws 

(d).

 -

Pivot the filter bracket rod against the FMA (e).

 -

Pull the filter downwards and tilt to remove (f).

 -

Once the new filter has been fitted, slide it against 

the rod, hold it securely and refit the filter access 

panel.

 - Tighten the 4 screws (d).

 

-

Option 3

 -

Undo the 4 screws on the filter access panel (h).

 -

Guide the filter access panel and filter downwards 

(i).

 -

Once the new filter has been fitted, hold it securely 

and refit the filter access panel.

 - Tighten the 4 screws (d).

 

Accessing the filter (Fig.13), LI/LY models:

 - Mark the 2 retaining lugs (k) positioned on the 

micro perforated return air grille.

 - Push the 2 lugs to release the return air grille.

 - Lower the hinge-mounted return air grille until it is 

at right angles to the diffuser.

 -

Release the filter (l) from its housing.

 -

After fitting a new filter, refit the return air grille. 

Lock it to the panel by simultaneously pushing the 

2 lugs sharply upwards.

 -

Check that the grille is securely affixed.

5.2 - 

Condensate drain pan

The main condensate drain pan and the pan extension 

must be kept clean. The pans and drainage fittings may 

be completely cleaned using non-abrasive, water-based 

detergents. Also check periodically that the drain pipe 

is not blocked, bent or kinked, and has the required 

gradient of -0°/+2 along its entire length. 
Before starting up the unit, check that the water flows 

properly into the condensate pan by pouring some water 

into it.

 

 EN-27  

COMFORT LINE

TM

Содержание COMFORT LINE

Страница 1: ...COMFORT LINE TM 06 2022 EN7533229 03 Instruction manual...

Страница 2: ...COLIS PACKAGE 35 kg Haut Top Bas Bottom C O L IS P A C K A G E COLIS PACKAGE 50 C 10 C COLIS PACKAGE COMFORT LINETM II...

Страница 3: ...Fig 1 b a e j i p f o h n m c g i d k n q III COMFORT LINETM...

Страница 4: ...sure Elec Element Ph Hz V P moteur Motor P W I moteur Motor I A Elec Element P W I A Cablage Wiring N Declaration CE Elec Diagram tr mn 1 r p m 2016 02461545 0001 E39H TH8 230TH14 7412910 430615 CFL12...

Страница 5: ...Fig 4 Fig 5 a b a c V COMFORT LINETM...

Страница 6: ...Fig 6 148 50 40 120 T1 128 T2 T3 160 T4 T5 193 T6 40 32 20 55 200 a b Fig 8 a b Fig 7 COMFORT LINETM VI...

Страница 7: ...Fig 10 Fig 9 a b VII COMFORT LINETM...

Страница 8: ...Fig 12 Fig 11 a d e b c COMFORT LINETM VIII...

Страница 9: ...i k b a a d d f g j i Fig 13 c e h h IX COMFORT LINETM...

Страница 10: ...Fig 14 b a c c d d e f COMFORT LINETM X...

Страница 11: ...Fig 15 a b b c d d e XI COMFORT LINETM...

Страница 12: ...Fig 16 Fig 17 e f b e h g COMFORT LINETM XII...

Страница 13: ...Fig 18 a a b XIII COMFORT LINETM...

Страница 14: ...LI LY T1 290 T2 T3 320 T4 355 T0 485 T1 T2 692 T3 T4 992 T5 T6 1292 T0 780 T1 T2 898 T3 T4 1198 T5 T6 1498 T0 225 T1 T6 209 134 75 COMFORT LINETM Poids Weight Gewicht Peso Peso Gewicht a rl k T0 T1 T2...

Страница 15: ...4 2 Air connections 20 4 3 Hydraulic connections 20 4 4 Condensate pump draining connection 22 4 5 Connecting the condensate drain pump option 22 4 6 Electrical connections 24 5 SERVICING AND MAINTENA...

Страница 16: ...ce It is the recipient s duty to inspect the contents of the packages upon receipt In the event of missing items the customer must provide the exact number of parcels delivered If any damage is found...

Страница 17: ...ce The unit should preferably be lifted by its mounting holes Fig 1 m and never by the condensate pan or the collars It is possible to carry out the installation using a fork lift truck as long as car...

Страница 18: ...rence I Motor speed wiring J Maximum operating pressure K Electric heater specifications if fitted L EC declaration number This device may be used by children aged eight and over and by persons with l...

Страница 19: ...ly plenum with collars for round ducts U Return and supply plenum with lateral collar for round ducts LI Air recovery grille integrated into the device with air supply via rectangular sleeve LIk LI mo...

Страница 20: ...er for the supply or return air 4 2 2 Fresh air knockout If the fresh air return leads directly outside the duct must not exceed 5 metres in length The fresh air temperature must not be below 10 C A r...

Страница 21: ...nd if necessary pressure relief valves 4 3 3 Filtration An efficient filtration system recommended mesh size of 0 5 mm should be fitted on the supply water and return water lines 4 3 4 Flushing The sy...

Страница 22: ...it The installer can change the condensate draining side by switching the bushing and the cap fig 9 b The drain pipe can be separate for each unit or connected to a main drain pipe sized to allow the...

Страница 23: ...7 2 metres 16 15 14 13 5 4 metres 11 5 11 10 5 10 6 metres 8 5 7 5 6 5 8 metres 6 5 4 10 metres 4 3 5 2 5 Under operating conditions outside of the temperature and relative humidity ranges recommended...

Страница 24: ...RT LINETM Motor reference AC Asynchronous Motor HEE Brushless Motor T0 T1 T2 T3 T4 T5 T6 T0 T1 T2 T3 T4 T5 T6 Max power input W V5 71 74 119 166 180 223 611 48 37 72 113 97 172 343 V4 48 48 104 124 12...

Страница 25: ...screwdriver this ensures a secure contact Repeat the procedure for the remaining customer speeds The wires coming from the motor and connected to terminals V1 to V5 must never be interconnected It is...

Страница 26: ...down allows post ventilation of the comfort unit for at least 2 minutes To ensure the hot water and electrical heaters work correctly when used simultaneously we recommend only low temperature setting...

Страница 27: ...he filter Fig 13 I Y H U models Option 1 Mark the 2 screws on the filter bracket runner a Undo the screws b Guide the filter downwards into its runner c Release the filter from its housing Once the ne...

Страница 28: ...assembly bundle Remove the removable lower panel a using the 4 screws Remove the removable panel For size 0 ensure the filter is guided downwards as the only support is provided by the removable panel...

Страница 29: ...ciency of the unit If necessary clean the coil with a vacuum cleaner taking care not to damage the fins If the coil must be disassembled on account of a leak Disconnect the electrical supply to the un...

Страница 30: ...esign for Energy Related Products and Energy Information Regulations 2019 and following amendments UK REACH Regulations 2019 UK Importer Toshiba Carrier UK Ltd Porsham Close Roborough Plymouth PL6 7DB...

Страница 31: ...roved channels for waste electrical and electronic equipment WEEE Check whether any part of the unit can be recycled for another purpose Sort the components according to their material for recycling o...

Страница 32: ...Manufacturer Carrier S C S Rte de Thil 01120 Montluel France Printed in the European Union Manufacturer reserves the right to change any product specifications without notice...