Installation Manual
Page 37 of 42
CIAS Elettronica S.r.l.
20MACIE0186 Ed. S001
SIOUX LIGHT
-Connection cable between serial lines (LINE1 or LINE2 ) of the Sioux-CU and first Sioux-Slave
Pin
Function Sioux Slave
Wire Colour
Function Terminal Block
Sioux CU
Terminal
1
GND
White/Orange
GND
2
2
GND
Orange
GND
2
3
GND
White/Green
GND
2
4
GND
Blue
GND
2
5
Power Supply 13,8 Vcc
Green
Power Supply 13,8 Vcc
1
6
Power Supply 13,8 Vcc
White/Blue
Power Supply 13,8 Vcc
1
7
RS485- Low Line LO
White/Brown
RS485- Low Line LO
4
8
RS485- High Line LH
Brown
RS485- High Line LH
3
Shell Shield
Shield
Shield
5
REMARKS:
-
Connect White/Orange, Orange, White/Green, and Blue wires together to
terminal 2 (GND) of the Sioux CU terminal block
-
Connect Green and White/Blue wires together to terminal 1 (Vcc) of the Sioux
CU terminal block
-Power and battery connections