![cias SIOUX Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/cias/sioux/sioux_installation-manual_2606607027.webp)
Installation Manual
Page 27 of 42
CIAS Elettronica S.r.l.
20MACIE0186 Ed. S001
SIOUX LIGHT
2.4 System configuration
Use the “Sioux test” software program to configure the system.
With this software it is possible to divide the global system into many sub-systems comprising
maximum one Sioux-CU, 4 master and 24 slave in total 28 sensors.
Each sub-system can then be sub-divided into a maximum of 4 zones and each zone can be
assigned the required characteristics (intrusion alarm threshold, cut alarm threshold, etc.).
It is possible to assign the characteristics not only by zone but also by individual sensor. For a
more detailed description see the “Sioux test” manual.
3. CONNECTIONS
3.1 Circuit descriptions and functions
The following pages show the SIOUX components describing their various functions.
The system, in the maximum configuration, is designed for the protection of 280m of fence and
is made up of the following components:
1 Sioux-CU board + associated housing
4 Sioux Master associated housings
24 Sioux Slave associated housings
The connections between the sensors will be with pre-composed CIAS cables.
The connections to Sioux CU includes:
2
RS485 serial lines for connection of the sensors with associated power supplies
1
RS485 serial line for connection to the IB System R or to the relay board
1
Ethernet line to connect to the configuration SW
1
USB device line to connect to the configuration software (Sioux Test)