CIAS Elettronica S.r.l.
Ed.
.2.4
Installation Manual
Pag. 36 of 36
Murena/Murena-Plus24
6.2 Functional Characteristics
1)
Generation
Of a true RADAR signal (Radio Detection And Ranging)
2)
Analysis
Of the RADAR signal using DSP
3)
Analysis
And filtering in the time domain FFT
4)
Analysis
Of the target distance using FUZZY control
5)
Analysis
Of the target speed using FUZZY control
6)
Analysis
Of the target size using FUZZY control
7)
Analysis
Of the direction of movement
8)
Analysis
Of the threat of the target according to FUZZY control
Analysis
For discrimination between rain and a true target
Analysis
For discrimination between noise and a true target
Analysis
Of the maximum detection distance setting LRTD Long Range Target Discrimination
Analysis
Of the minimum detection distance setting SRTD Short Range Target Discrimination
Analysis
Of masking
9)
Analysis
Of the power supply voltage, High or Low.
10)
Analysis
Of the ambient temperature to detect events outside the normal operating range and to
compensate for differences in signal due to temperature changes.
11)
Analysis
Of opening the cover (Radome).
12)
Analysis *
Of a Stand-by input to inhibit the recording of events in the History and Monitor internal memories
of the Murena.
13)
Analysis *
Of a Test input which activates an internal test of the Murena and opens the alarm relay if the test
is successful (it creates an alarm status on the serial line with the Murena Plus).
14)
Activation
Of three static relays for alarm, tamper and fault.
15)
Activation *
Of sequential polling of the pre-alarm, alarm and tamper status on an RS485 serial line for
connection with the IB-System interface.
16)
Activation
Of three leds for the indication of alarm, tamper and fault.
Activation
Of 6 multi-functional led to show the distance or dimensions of the target or entering alarm
condition.
Activation
Of the buzzer during walk tests on reaching an alarm condition.
Availability
Of a set of switches to activate the functions and to define of the entity.
17)
Availability
Of a lithium battery to maintain the data in the total absence of power.
18)
Availability
Of a clock and calendar to provide a date and time stamp for the events stored within the Murena
as either history or monitor events.
19)
Availability *
Of a historical event archive, able to store up to 256 events with indication of the date, time, type of
event and the values (in case they are specific to the event). This data can be acquired using the
Wave Test 2
software and stored in historical files that can be viewed and/or printed.
20)
Availability *
Of an archive of up to 256 recordings, each 6.5 seconds long, of the detected analogue signal of
the distance, speed and size of the target when this last parameter is above the pre-alarm
threshold setting.
21)
Availability
Of a set of default parameters, which can be used from time to time if the Murena is not set for any
reason or if, during a self diagnosis, it detects an incorrect value.
22)
Availability *
Of a connector for the connection of a PC via an RS-485 serial line, which allows the use of the
Wave Test 2
for configuration, test and management of the detector.
23)
Availability *
Of an RS-485 serial line connection, which allows the connection of all the detectors on a common
line, acquiring all the alarms over the line, issuing Stand-by and Test commands and carrying out
calibration and management.
The functions marked with “*” are only active on the Murena Plus, Murena Plus24 and
Murena Plus Curtain version.