3.  INSTALLATION 

 

3.1.  MACHINE HANDLING 

 

 

 

The chocolate display cabinet handling, from the truck to the final place, has to be made 
by  any  truck-lift,  which  is  proper  to  its  weight.  The  display  cabinet  shall  be  always 
balanced in order to ensure personnel integrity and machine functionality   

 

   

 

     
 
 
 
 
 
 
     

 

 

The cabinet can be shipped with or without wood packaging, in case wood crate will be 
used, will have a pallet base for an easy fork-lift handling. The pallet, however should be 
handle in the central position

 

 

 

 

During  the  shipment,  it  is  necessary  to  avoid  any  crash  or/and  shake  of  the  display 
cabinet in order to not damage its frame, especially its glasses. 

 

 

 

Do not drag the display cabinet on the floor and do not push it on the upper glasses. 

 

 

3.2.   STOCK OF THE DISPLAY CABINET 

 

 

Whenever the cabinet has to be stoked, follow carefully what suggested before. 

 

Environmental temperature during the cabinet stock can have following range -15°C and + 55°C and humidity between 30% and 90%. 

 

The display cabinet has always to be protected by sunrays and raining. 

 

In case the display cabinet has to remain in stock quite long time before its use, keep it with its packaging in order to maintain its protection. 

 

3.3.   PACKAGING REMOVE 

 

Before getting the display cabinet from the forwarding agent, check its conditions. In case it will be some damages, inform the driver and sign it on 
shipping documents. 

Eventual damages relevant to the shipment and/or to the wrong stock, have not to be ascribed to the manufacturer. 

 

3.4.   DISPLAY CABINET POSITION 

 

The refrigerated display cabinet needs particular environmental conditions in order to offer the right performance, so that the area where it will be 
used has to respect following indications   

 

 

 

Floor has to be levelled perfectly, on the contrary keep the display cabinet on the horizontal position in order to guarantee a perfect defrosting 
water drain and avoid boring compressor noises.  

 

 

The display cabinet has to not be under the sun-rays in order to have its better refrigeration performance, has to remain inside the local or to 
be sheltered by window curtain. If what described above is not observed, it can determinate an increase of temperature of displayed product 
and an increasing power consume.  

 

 

The display cabinet has not to be under air currents due to open doors or windows, or under roof ventilators or under air condition outlets. 
In case will be not respected the above suggestions it can arise an increasing of temperature of the displayed product and/or an increasing ice 
phenomena on the evaporator and internal fans, which compromise the correct cold air circulation and product consistence. 

 

 

The display cabinet has not to be placed close any heat source as heaters, ovens, etc. 

 

 

The display cabinet has to have a sufficient place in order to ensure a correct custom service, to make an easy maintenance operation, to 
guarantee the right air flow necessary to make cold the condenser. Besides the warm air which flows out has to no have any obstacle or to 
invest other equipments in order to not reduce the correct functions.  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание 6040 Series

Страница 1: ...Refrigerated Pastry Showcase 6040 SERIES Maintenance And Use Manual CIAMspa 06081 Petrignano d Assisi PG Italy tel 075 80161 Fax 075 8016215 http www ciamgroup it e mail info ciamgroup it...

Страница 2: ...or refrigerators freezers and ice machines 1 4 RESPONSIBILITY Ciam declines any responsibility relevant to damages on persons animals and or products in case of No respect of in force norms Installati...

Страница 3: ...ong stock have not to be ascribed to the manufacturer 3 4 DISPLAY CABINET POSITION The refrigerated display cabinet needs particular environmental conditions in order to offer the right performance so...

Страница 4: ...et in order to make easy any type of check and maintenance operations When the condensing units are external will be necessary a frame holder that has to be fixed in a proper way and eventually added...

Страница 5: ...a wet cloth weekly Additional defrost Under particular conditions of temperature and humidity the frost that normally forms on the evaporator and fans might increase in volume so leading to a faulty f...

Страница 6: ...G ELEMENT SUCTION AIR GLASS HEATING ELEMENT OUTLET AIR HEATING ELEMENT REAR GLASS HEATING ELEMENT INTERNAL GLASS HEATING ELEMENT FRONT GLASS UPPER FRAME HEATING ELEMENT FRONT GLASS LATERAL LOWER FRAME...

Страница 7: ......

Страница 8: ......

Страница 9: ...s length is set in the Fdt parameter With Fdt 0 the dripping time is disabled 3 3 CONTROL OF EVAPORATOR FANS The fan control mode is selected by means of the FnC parameter FnC C_n fans will switch ON...

Страница 10: ...THE HIDDEN MENU TO THE FIRST LEVEL AND VICEVERSA Each parameter present in the HIDDEN MENU can be removed or put into THE FIRST LEVEL user level by pressing SET n In HIDDEN MENU when a parameter is p...

Страница 11: ...ture alarm delay 0 255 min time interval between the detection of an alarm condition and alarm signalling dAO Exclusion of temperature alarm at start up from 0 0 min to 23 5h time interval between the...

Страница 12: ...TORING SYSTEMS The TTL serial line available through the HOT KEY connector allows by means of the external TTL RS485 converter XJ485 CX to connect the instrument to a monitoring system ModBUS RTU comp...

Страница 13: ...ous cycle duration 0 0 24 0h 0 0 Pr2 CCS Set point for continuous cycle 55 0 150 0 C 67 302 F 5 Pr2 COn Compressor ON time with faulty probe 0 255 min 15 Pr2 COF Compressor OFF time with faulty probe...

Страница 14: ...50 min nu 13 0 rtc Sd3 3rd holiday defrost start 0 23h 50 min nu 21 0 rtc Sd4 4th holiday defrost start 0 23h 50 min nu 0 0 rtc Sd5 5th holiday defrost start 0 23h 50 min nu 0 0 rtc Sd6 6th holiday de...

Страница 15: ...standard way for controller without RTC with EdF rtc the defrost is made in real time depending on the hours set in the parameters Ld1 Ld6 on workdays and in Sd1 Sd6 in holidays Other parameters are u...

Страница 16: ...visualization rEd X REP display optional P1 P2 P3 P4 SET dtr it selects which probe is displayed by X REP P1 Thermostat probe P2 Evaporator probe P3 Third probe only for model with this option enabled...

Страница 17: ...will restart only if the digital input is disabled otherwise the instrument will wait until the MdF safety time is expired 8 6 INVERSION OF THE KIND OF ACTION HEATING COOLING i1F Htr This function all...

Страница 18: ...XW20LS DIRECT CONNECTIONS OF LOAD Supply 120Vac or 24Vac connect to terminals 5 6 The X REP output is optional 17 DEFAULT SETTING VALUES Label Name Range C F Level Set Set point LS US 3 0 rtc Real tim...

Страница 19: ...start 0 23h 50 min nu 0 0 rtc Sd6 6th holiday defrost start 0 23h 50 min nu 0 0 rtc Adr Serial address 1 247 1 Pr2 PbC Kind of probe Ptc ntc ntc Pr2 onF on off key enabling nu oFF ES oFF Pr2 dP1 Room...

Отзывы: