background image

PROTEC4

4

 zones burglary central unit

IT

A

L

IA

N

O

E

N

G

L

IS

H

USER’S MANUAL

Содержание PROTEC4

Страница 1: ...PROTEC4 4 zones burglary central unit ITALIANO ENGLISH USER S MANUAL...

Страница 2: ...time regulation 27 3 3 Alarm time regulation 27 Chapter 4 Operating 28 4 1 Panel description 28 4 2 System enabling 29 4 2 1 Enabling by the front panel key 29 4 2 2 Enabling by other command system...

Страница 3: ...g with the piezoelectric SP31 siren for inside use telephonic with the TD81 telephone dialer 1 2 Operating features 4 protection zones 1 delayed 2 immediate 1 24 hours with alarm memory All zones sing...

Страница 4: ...Maximum current supplied on services output 650mA Fuse on services output voltage F type 1A Maximum current supplied on sirens output 3A connected to the battery Sirens output fuse Tipo F 3 15A Maximu...

Страница 5: ...l unit must be connected with an alarm system according to CEI 79 3 Standard or similar 2 2 Power supply It s important to know that the entire system is powered exclusively by the 12V 7 5Ah lead batt...

Страница 6: ...NC line immediated NC line immediated NC line immediated 12 16 NC line delayed If the alarm zones are not used the clamps must be arched The PROTEC4 and the AL5 don t need the ground connection but fo...

Страница 7: ...is connection will activate the 24h anti sabotage protection alarm when a false key is inserted in the SKI connector 23 Installation In series to the 24h line ATTENTION Optional connection A B C D SKI...

Страница 8: ...rminal boards becouse this central unit hasn t got an impulse counter Use the SCHSW impulse counter board to connect the switch contact for rolling shutters type C778 or use the switch contact for rol...

Страница 9: ...25 2 3 3 Telephone dialer Phone line TD81 2B4 In series to the 24h line Installation...

Страница 10: ...26 2 3 4 Sirens SP31 SA310 2B2 2B2 In series to the 24h line PROTEC4 User s manual...

Страница 11: ...he entering time allows the system user to access the protected environments and reach the central unit to disable the system During this time a possible activation of the sensors installed on the zon...

Страница 12: ...EMORIAALLARME button pressed ALARM MEMORY visualization released zone status visualization On system disabled by pressing this button the blinking zones status control LEDs e indicate the ALARM MEMORY...

Страница 13: ...c key system a proximity key system or an electronic keypad system is installed outside of the protected areas it s necessary to leave the key switch ALWAYS in the ON position All the SKI connector fo...

Страница 14: ...for the electronic key the PXR reader for the proximity key and the KBC KBM and KBT keypads have two LEDs one green and one red indicating the central unit status see table beside To disable the syst...

Страница 15: ...tes an alarm cycle The alarm is active for the alarm time setted par 3 3 This zone is excludible from the front panel 4 5 3 Zone 3 delayed On system enabled the opening of the NC line activates an ala...

Страница 16: ...nected to the AL5 power supplier battery charger and the battery inside of the self powered sirens For the central unit cleaning use only a soft and humid cloth No use absolutely diluents and abrasive...