27
Specification
Unit name
Model name
Net weight
Climate class
Hot water
Cold water
Ice making
Max
Sparkling water
Power
consumption
Ambient water
Hot/Cold water
Ice
Room temperature
Ice making cycle
Daily ice making capacity
Ice weight
Reservoir
capacity
Ice making
capability
(This can differ
depending on room
temperature)
IGUASSU SPARKLING RO
CHP-5361DL
22 kg
1,640 W
96 W
90 W
1,800 W
0.7
ℓ
2.4
ℓ
0.57
ℓ
/ 1.6
ℓ
0.52 kg
N class(90 °F
±
1 °F)(32 °C
±
1 °C)
10 g
±
1 gX6 EA / cycle
290 W X 520 D X 475 H(mm)
Reciprocating type
Wire condenser type (Forced convection)
Thermistor
Thermistor
Bimetal (Manual return)
Over heating prevention system, Water level detecting
system, Water leakage stop valve, Fuse
Capacitance sensor
1.6 m
IPX1
20
。
C
16 min
±
1 min / cycle
5.0 kg / day
30
。
C
19 min
±
1 min / cycle
4.0 kg / day
External dimension
Compressor
Heat radiation type
Cold water temperature regulation
Hot water temperature regulation
Overheating prevention system
Safety system
Cold water tank water level adjustment
Power cord
IP class
※
“N class” indicates temperate climate.
※
IP class stands for “International protection” against water.
※
Reservoir capacity can be different from indicated capacity.