SETTING EACH PART    

 
1    Set the “FILTER” into the outer case. 

 
2.    Set  the  “WATER  TANK”  and  “BURNER  SET”  into  the  outer 

case. 

Note:  Put  a  Water  Tank  in  the  roaster  unit  after  setting  a 

Burner Set 

to a Water Tank beforehand; can be easily done. 

 

Check  whether  a  projection  at  leg  of  the  burner  is  set  into  a  hole  on 
the water tank , and the burner-set should be set correctly and firmly. 

Improper setting of Burner Set will cause to incomplete combustion or 
ignition failure 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
Gripper 

for 

Water 

Tank 

Small 

Trivet 

(

Option

Large Trivet 
(Option) 

Gripper 

for 

Charcoal 

Por

Water Tank 

Burner 

Set 

Содержание NJG-C

Страница 1: ...his manual for your immediate and future references Warning Check your local gas supplier for the proper instructions to follow in the event the user smells gas These instructions shall be posted in a...

Страница 2: ...n operating instructions thoroughly before installing or servicing this equipment The following cautions indicate important safety subjects please follow these directions to prevent injury or property...

Страница 3: ...damage Samples of sign Caution Electric Shock Indicates cautions including warnings Contents of the caution are shown in or around with pictures or words The sign in the left shows Caution Electric S...

Страница 4: ...per gas source will cause fire burns or carbon monoxide poisoning or mechanical troubles If the gas source is not clear contact the distributor of the roaster or the gas supplier Out of Order In case...

Страница 5: ...l examination the ventilating system during normal maintenance and clearing Warning For safety reason before operation check the clearance to combustible and non combustible construction such as floor...

Страница 6: ...use overheating Forbidden Never disassemble or remodel the roaster Remodeling or disassembling may cause abnormal operation or troubles Contact your local service representative or the factory if you...

Страница 7: ...te combustion or mechanical troubles No Installment Never use the roaster for any purpose other than the original usage specified by the manufactures Improper usage will may cause injury or property d...

Страница 8: ...The roasting plate grilling mesh and roaster body are hot when in operation or just after using the roaster never touch them except the control part Touching the heated parts may cause burns Caution...

Страница 9: ...on or damage Pull the Plug Out MAIN PARTS Roasting Plate Top Ring Burner Set Water Tank F V Damper under the Outer Case Grey color one Louver small Filter Outer Case Louver Large Charcoal Tray Charcoa...

Страница 10: ...er setting a Burner Set to a Water Tank beforehand can be easily done Check whether a projection at leg of the burner is set into a hole on the water tank and the burner set should be set correctly an...

Страница 11: ...NG POT Note 3 When putting water pay attention not to splash water onto the burner and or burner head Splashed or wet burner burner head will cause to ignition failure Burner Set Watering Pot Flame Ro...

Страница 12: ...d Flame Adjustment Warning Operate the exhaust fan before igniting Without ventilation the roaster will burn incompletely and cause carbon monoxide poisoning injury or fire If the table cover table li...

Страница 13: ...losed Position wait 15 seconds and try to ignite again Work of the re ignition within 15 seconds can not be done due to a mechanism of the safety device s working 3 After igniting the gas turn ON the...

Страница 14: ...stment of Blowing Power Heat Power of Charcoal For adjusting blowing power turn the Blower Fan Control Knob For the High power turn the knob clockwise and for the Low power turn the knob counter clock...

Страница 15: ...burns Do not shut off ventilation and exhaust fans until the charcoal has been removed or completely extinguished EXTINGUISHING after operation 1 Turn OFF the blower fan switch Check the gas control...

Страница 16: ...Ring Charcoal Tray Charcoal Pot and Water Tank Wash the top ring charcoal tray charcoal pot and water tank with neutral detergent each time it becomes dirty every day Use caution when handling these...

Страница 17: ...completely c For Flame Rod Please clean regularly In case the flame rod is immersed or washed in water dry it completely Stuck oil dirt or wet on around the area will cause error temperature failure t...

Страница 18: ...FAILURE SAFETY DEVICE Therefore always keep the area around the detector clean with wiping regularly The electrode spring is transformed easily and handle it carefully 7 F V Damper Fire Volume Damper...

Страница 19: ...Gas Burner Electrical 220V 1Ph 50 60Hz Electric Consumption 300 W Water Tank Capacity 2 500 cc Required Exhaust Air Volume 300 m3 h Required Fresh Air Supply Volume 300 m3 h Cooing Load 6 63 kW Gas C...

Страница 20: ...TADA KUWANA MIE 511 0943 JAPAN PHONE 81 594 31 2221 FAX 81 594 31 How to change Thermal Fuse This photograph shows a normal state This photograph shows the state that a thermal fuse blows out Thermal...

Страница 21: ...21 Pin Lock portion Lever Turn the lever counterclockwise Hang the Lock portion on a pin of a fuse holder...

Отзывы: