background image

 

Anchoring your safe 

The Professional S2 safe is supplied with anchors for floors with solid concrete 

bases. A minimum of 100mm depth is needed to correctly bolt down your safe. 
Take care to note the positions of any services or damp proof coarse which might 
be installed and avoid anchoring in these areas. 

 
 
Position your safe in its final location and using a 
pencil or similar mark the centre of each 
anchoring hole onto the floor below. 
 
Use masking tape to mark the position of the 
corner of the safe – this will help later when the 
safe has to be repositioned. 

 

Remove the safe temporarily. 
 
Using a 12mm diameter masonry bit and 
percussion drill, create two holes each 90mm 
deep in the positions previously marked. 

Remove drilling debris and dust from both holes. 

 
 

Reposition your safe making sure the holes in the 
base line up with the holes in the floor. 
 
Gently tap both anchor bolts into place. The 
washers will prevent the bolts from passing 
directly through. 
Using a 15mm hexagonal spanner tighten the nut 
until it comes to a stop.  
Recommended torque setting 50Nm

 

 

www.chubbsafes.com

 

“Chubb” is owned by Chubb plc and is a registered trademark used under license 

Содержание Professional S2

Страница 1: ...USER GUIDE PROFESSIONAL S2 SAFE www chubbsafes com Chubb is owned by Chubb plc and is a registered trademark used under license ELECTRONIC LOCK USER GUIDE...

Страница 2: ...and green LED to flash twice The green LED will then flash for a further 7 seconds THE HANDLE MUST BE TURNED WITHIN THIS 7 SECONDS PERIOD otherwise the safe will return to the locked state Entering an...

Страница 3: ...xtend the door bolts 2 The safe is now locked Programming Codes 1 Programming the Primary Code Press ON Press ENTER Press 1 Press ENTER Input the valid primary code 1 2 3 4 5 6 initially and press ENT...

Страница 4: ...m 6 to 8 figures and press ENTER Re enter the user code and press ENTER Audio and visual signals are the same as for the primary code programming 3 Programming the User Code without the Primary Code P...

Страница 5: ...s enter a valid code and open the safe by turning the handle clockwise Battery Requirements Model 6LR61 Voltage 9V Battery Type ALKALINE Changing the Battery In order to change the main battery it is...

Страница 6: ...of the time delay period 1 9 minutes e g entering 053 a time delay of 5 minutes followed by 3 minutes in which the safe should be opened Press ENTER the green LED flashes twice Opening the safe with...

Страница 7: ...TER buzzer and green LED will operate twice Activation deactivation of the buzzer To turn on or off the sound Press the ON button buzzer will sound and green LED will flash Press the ENTER button buzz...

Страница 8: ...f the corner of the safe this will help later when the safe has to be repositioned Remove the safe temporarily Using a 12mm diameter masonry bit and percussion drill create two holes each 90mm deep in...

Отзывы: