PCB Layout
①
LED On/Off
②
Working Mode
Setting
⑤
Tamper Switch
③
Battery
⑥
Zone Mode Setting
④
Microwave Sensitive Adjustment
3.7V 18650
1. LED options: ON/OFF (default setting is ON).
2. Working mode options: 10S=Test mode, 5MIN=Power saving mode
(default setting is test mode).
3. Battery: One piece of 18650 rechargeable lithium battery.
4. Microwave sensitivity adjustment options: HIGH, MEDIUM, LOW.
(default setting is medium).
5. Tamper switch: In working state, if the housing is opened, detector
will send alarm signal.
6. Zone mode options: Normal zone, home zone, 24-H zone (default
setting is normal zone).
You can change the zone mode of this detector as follows:
Open the rear cover of the detector, change the array of jumpers to
the corresponding position as below:
Normal zone:
In arm or home arm state, the detector set at normal
zone will trigger an alarm once intrusion is detected.
Home zone:
In home arm state, the detector set at home zone is
disarmed.
24-H zone:
The detector set at 24-H zone will trigger an alarm once
intrusion is detected, no matter the system is armed or disarmed.
Detection Scope
Top view
Side view
2m
4m
6m
8m
0m
0m
2m
110°
Working Mode Selection
After the battery is loaded, the detector enters into 1 min self-
testing with the red and orange LEDs flashing continuously, and
then it starts to work according to the pre-set working mode.
5 MIN
10 S
5 MIN
10 S
Testing Mode
Power Saving Mode