14-1 Forced Removal of System Data
This function is used to clear all the patterns and system data stored in the machine, so be sure to perform a backup
of all data (refer to 2.6.2.9 for backup operations) before removing them; you can clear the data with the following
steps:
1. After the machine is stopped, cut the data line connected with the synchronizer, then the following menu will
appear on the screen. (Under normal circumstances, if the "Synchronizer or synchronizer connection line error"
appears on the screen, check whether the synchronizer’s connection data line is connected properly);
2. Connect the zero point sensor using a sheet metal, so that it remains ON state, click the icon in the upper left
corner of the screen, the following prompt menu appears, press OK, a password input interface automatically pops
up, enter 5211, the menu will automatically jump to the system parameter restoration menu.
点 此 进 入
数据清除
Encoder error
Encoder error
Encoder connection error!
Encoder connection error!
Repair and turn on the power again
Repair and turn on the power again
Click here to enter
data removal
Encoder error
Prompt
Restore the default system parameters?
Confirm
Cancel