background image

3

ELECTRIC SHOCK HAZARD. Any installation involv-
ing electric heaters must be performed by a quali-
fied person and must be effectively grounded in
accordance with the National Electrical Code to
eliminate shock hazard.

Note:

All wiring should be done in accordance with local codes

and the National Electrical Code by a qualified person.

1.

Electrical wiring enters heater case through 7/8” opening in end of
heater.

2.

Grounding conductor, with green insulation, should be secured to
grounding screw located on case.

OPERATION

HAZARD OF FIRE OR DISCOLORATION OF TEM-
PERATURE SENSITIVE FABRICS. Keep combustible
materials and such fabrics at least 4” away from
front of cover or above cover.

FIRE HAZARD. This heater is not intended for use in
hazardous atmospheres where flammable vapors,
gases, liquids or other combustible atmospheres are
present as defined in the National Electrical Code.
Failure to comply can result in explosion or fire.

ELECTRIC SHOCK HAZARD. Disconnect all power
before attempting to service this heater.

1.

Following long periods of idleness, heater should be vacuumed
before start-up to remove accumulated combustible particles

which will incinerate causing smoking and consequent wall dis-
coloration.

2.

If heater is located in areas of heavy traffic, furnish suitable heater
guard (wall mounted pipe rail in front of case, for example) to pre-
vent damage to heater.

MAINTENANCE

WIRING

RENEWAL PARTS IDENTIFICATION

Reflector

Wall

Element

Air Space Between Wall and Heat

In

su

lating

In

su

lating

H

e

at

er

Mo

de

l

Volt

s

Watt

s

H

e

ating El

e

m

e

nt

B

us

hing

B

us

hing

Cov

er

120

1000

SE-1850 – 120V - 500W (2)

032-010978-001 (4)

032-010978-002 (4)

152-108257-001

H-1801

240

1000

SE-1850 – 240V - 500W (2)

032-010978-001 (4)

032-010978-002 (4)

152-108257-001

480

1000

SE-1850 – 240V - 500W (2)

032-010978-001 (4)

032-010978-002 (4)

152-108257-001

120

1500

SE-2475 – 120V - 750W (2)

032-010978-001 (4)

032-010978-002 (4)

152-108257-002

H-2405

240

1500

SE-2475 – 240V - 750W (2)

032-010978-001 (4)

032-010978-002 (4)

152-108257-002

480

1500

SE-2475 – 240V - 750W (2)

032-010978-001 (4)

032-010978-002 (4)

152-108257-002

120

2000

SE-2450 – 120V - 500W (4)

032-010978-001 (8)

032-010978-002 (8)

152-108257-003

H-2406

240

2000

SE-2450 – 240V - 500W (4)

032-010978-001 (8)

032-010978-002 (8)

152-108257-003

480

2000

SE-2450 – 240V - 500W (4)

032-010978-001 (8)

032-010978-002 (8)

152-108257-003

120

3000

SE-2475 – 120V - 750W (4)

032-010978-001 (8)

032-010978-002 (8)

152-108257-003

H-2407

240

3000

SE-2475 – 240V - 750W (4)

032-010978-001 (8)

032-010978-002 (8)

152-108257-003

480

3000

SE-2475 – 240V - 750W (4)

032-010978-001 (8)

032-010978-002 (8)

152-108257-003

1

3

5

4

Отзывы: