background image

1.

Unpack the heater from the carton and remove the front panel.

Note:

The front panel screws are recessed at the bottom of the

front panel at each end of the heater.

2.

Remove the desired terminal box covers and wire supply
knockouts from the terminal box area.

3.

Use trim frame as a template to drill holes into the top, bottom
and sides of the heater using a 1/8” diameter drill bit.

4.

Secure the trim frame using the #8 screws provided with the
trim kit.

TIP:

The bottom trim may be omitted if the heater is to be

installed at floor level.

5.

Prepare the wall recess opening to accept the heater.

TIP: 

Leave approximately 1/2” clearance to insert the heater

cabinet.

6.

Secure the back plate into the recess opening using suitable
fasteners (Provided by customer).

7.

Proceed to the wiring instructions.

INSTALLATION (Recessed Wall)

WIRING

Note:

All wiring should be done in accordance with local codes

and the National Electrical Code by a qualified person.

1.

Run branch circuit wiring of proper voltage and wire size to the
location of the terminal box of the heater.

TIP:

Supply wire entry is commonly made into one heater.

Through wiring (factory furnished) can be used for connection
to adjacent heaters.

Recommended minimum supply wire sizes are listed in the table
below:

2.

Wire all heaters and controls in accordance with the appropri-
ate wiring diagram.

TIP: 

Sample wiring diagrams are provided on page 4.

3.

Wrap the supply ground wire to the green painted ground
screw and tighten.

Note:

When heaters are mounted end to end, remove the fin-

ishing end plate, install a chase nipple and locknut in the ter-
minal box to insure grounding continuity, and to protect the
wiring. (Figure 4)

Where heaters are spaced apart, remove the finishing plate and use
rigid conduit (provided by customer) for through wiring and
ground continuity. Do not exceed the allowable number of con-
ductors allowed by the National Electrical Code.

4.

Do a final and complete check of all wiring then replace the
terminal box covers.

5.

The front panel may now be installed.

WARNING:

To prevent the risk of fire, do not oper-

ate the heater without the front cover in place.

Insert the top of the front panel into the top flange of the heater.
Push the bottom flange of the front panel into place and secure
with screws.

Maintenance

The CAF-20 series heaters contain no moving parts. Occasional
vacuum cleaning of the cabinet interior is the only maintenance
required.

WARNING:

Before removing the front cover for

cleaning, make certain supply power is discon-
nected.

Maxim

u

m Watt

s

 

Per

 Ci

r

c

u

it U

s

ing 75°C. Wi

re

Ro

u

gh In

Wi

re

 

S

iz

e

1

20V

208V

2

4

0V

277V

34

7V

4

80V

600V

14

1440

2496

2880

3324

4164

5760

7200

Copper

12

1920

3328

3840

4432

5552

7680

9600

Wire

10

2880

4992

5760

6648

8328

11520

14400

T

er

minal Box Vol

u

m

es

 

(

C

u

bic Inch

es)

H

e

at

er

 

S

tyl

e

L

e

ft Han

d

 Box

Right Han

d

 Box

4

” Wi

de

5” Wi

de

CAF-20

379.75

474.75

Chase Nipples
Installation Between
Heaters Butted Together

Ground Wire Running
Through Chase Nipple

F

ig

ure

 

4

F

ig

ure

 5

Содержание CAF-20215

Страница 1: ... 3 3 000 7 2 10 236 48 3 53 CAF 20430 277 1 3 000 10 8 10 236 48 3 53 CAF 20430 480 1 3 000 6 3 10 236 48 3 53 CAF 20430 480 3 3 000 3 6 10 236 48 3 53 CAF 20440 208 1 4 000 19 2 13 648 48 3 53 CAF 20440 208 3 4 000 11 1 13 648 48 3 53 CAF 20440 240 1 4 000 16 7 13 648 48 3 53 CAF 20440 240 3 4 000 9 6 13 648 48 3 53 CAF 20440 277 1 4 000 14 4 13 648 48 3 53 CAF 20440 480 1 4 000 8 3 13 648 48 3 5...

Страница 2: ...uts from the terminal box area 3 Determine the correct mounting height and scribe or snap a level line on the wall to maintain each heater back plate in a horizontal alignment when mounting 4 Mount the back plate to the wall using suitable fasteners pro vided by customer using the scribed line on the wall to keep the heater level TIP Should the wall surface be uneven secure the heater back panel t...

Страница 3: ...d on page 4 3 Wrap the supply ground wire to the green painted ground screw and tighten Note When heaters are mounted end to end remove the fin ishing end plate install a chase nipple and locknut in the ter minal box to insure grounding continuity and to protect the wiring Figure 4 Where heaters are spaced apart remove the finishing plate and use rigid conduit provided by customer for through wiri...

Страница 4: ... Stat Heater 3 Pole Stat 3 Ph Parallel L1 L2 L3 L1 L2 L3 Element Heater LYD Relay 1 Ph Parallel Return Wire Unit Control L1 L2 2 T2 T1 Element Return Wire Unit Control Heater LVC Relay 1 Ph Parallel L2 L1 T0 T1 2 Element Return Wires Unit Control Heater 3 Pole Contactor 3 Ph Delta Contactor T0 T1 L1 L2 L3 24V Element Return Wires Unit Control Contactor Heater 3 Pole Contactor TX 3 Ph Delta T0 T1 L...

Отзывы: