background image

 

 

 

M8 Plus User Manual 

  V1.3 September 2012 

www.chroma-q.com 

Note:

 Full menu description on page 8. 

The M8 Plus is supplied power and control signals by means of two 4-pin XLR style connectors on the rear panel, allowing 

multiple units to be ‘daisy-chained’ into the same line of cabling. Patching the output from the last unit back into the power 

supply will terminate the DMX for each chain line and ensure even power voltage across all colour changers in that chain. 

Note:

 The quantity of M8 Plus colour changers, and maximum cable length per power supply output is dependant upon the 

size of PSU / Splitterbox used. (See later in this manual for details.) 

The rear of the Chroma-Q M8 Plus is designed to accept eight point standard mounting bracket for 8 light blinder fixtures. 

2. 

Operation 

2.1 

Unpacking the unit 

2.2 

Control and power cables 

2.3 

Mounting the unit 

2.4 

Operating the unit 

2.5 

Modes of operation 

2.6 

Troubleshooting 

2.7 

Technical overview 

2.8 

Technical specifications 

 

 
2.1 

Unpacking the unit 

The M8 Plus package includes 1 unit M8 Plus with safety chain. 

 

 
2.2 

Control and power cables 

The M8 Plus utilises an XLR 4-pin cable system. This is used for power and data transfer. Pins 2 and 3 are for ANSI E1.11 

USITT DMX 512-A data. Pins 1(-) and 4(+) are for 24VDC power. 

Damage  will  occur  if  power  connections  short  to  data  or  ground/shield  connections.  When  assembling  XLR  4-pin  cables, 

heat  shrink  should  be  used  on  each  individual  pin  to  prevent  short  circuits  (Tourflex  Ultra  Datasafe  P&D  cable 

recommended). See diagram below. 

Note:

    It is very important to ensure that the drain wire from the cable shield is connected to both XLR connector cases. 

 

 

 

Detail of connector wiring 

Содержание M8 Plus

Страница 1: ...Chroma Q M8 Plus User Manual Version 1 3 September 2012 PN 114 0501...

Страница 2: ...the above e by modification repair or service by anyone other than Chroma Q who has not applied for and been approved by Chroma Q to do such modification repair or service unless the Customer provides...

Страница 3: ...make alteration to devices and their functionality without notice due to our on going research and development The Chroma Q M8 Plus has been designed specifically for the professional entertainment l...

Страница 4: ...2 Control and power cables 5 2 3 Gel Loading and Replacement 6 2 4 Mounting the unit 8 2 5 Operating the unit 9 2 6 Modes of operation 10 2 7 Troubleshooting 14 2 8 Technical overview 15 2 9 Technica...

Страница 5: ...changer Provide a minimum clearance of 0 1 meters 4 inches around air vents Do not modify fixture accessory or install other than genuine Chroma Q parts Protection from injury due to falls When mounti...

Страница 6: ...racket for 8 light blinder fixtures 2 Operation 2 1 Unpacking the unit 2 2 Control and power cables 2 3 Mounting the unit 2 4 Operating the unit 2 5 Modes of operation 2 6 Troubleshooting 2 7 Technica...

Страница 7: ...line loss c It is recommended to use a return cable for each run This will ensure balanced DC power to all units where the line is correctly terminated and all units receive power if one link of the c...

Страница 8: ...hen installing gel string 1 Place the unit on a flat surface with motor fan electronics on your right hand side assuming you re loading from tail end of the string reverse if starting from the leader...

Страница 9: ...of the gel string to the Take Up Reel TUR Follow the centre line guide scribed on the TUR 3 Apply power to the unit while holding down the MENU button The display will show the legend PAL 4 Press and...

Страница 10: ...n Decreases the mode level or value UP Button Increases the mode level or value 3 digit display Displays mode monitor or blank display Push button operation The MENU button is used to scroll through t...

Страница 11: ...enu under dP where dP0 is OFF and dP1 is ON Reset If the MENU and the UP button are pressed and held for 1 second the unit will reset to the factory default settings This feature is particularly usefu...

Страница 12: ...crolling speed of the unit This feature allows the gel string to move at a higher speed for more rapid changes Use of this high speed will generate more noise from the unit Press the UP or DOWN button...

Страница 13: ...l reset the unit to the default settings While holding down MENU and UP button for 1 second P P P Power A A A Assisted L L L Loading PAL Load Used to load a gel string into the unit Hold down the MENU...

Страница 14: ...r DOWN to switch between on 1 and off 0 See also display mode instructions remote operation Mode1 single DMX channel operation Mode 2 Dual DMX channel operation Colour Fan speed Mode 3 Dual DMX channe...

Страница 15: ...cator is off Bad Cable No DMX at Splitter PSU Check cable and DMX run from console Units run at different speeds Colour changer speed settings may be different Cable lengths are too long No cable retu...

Страница 16: ...electronics problems are usually created by external factors such as shorted cables etc The 75176 transceivers are susceptible to damage if 24VDC is present on the DMX signal lines Routine maintenanc...

Страница 17: ...M8 Plus 3 Maintenance and Storage The M8 Plus should be stored in a dry and cool environment safely secured to prevent from falling on a hard surface The unit may be exposed to dirty environments con...

Страница 18: ...M8 Plus User Manual 17 V1 3 September 2012 www chroma q com 4 Drawings 4 1 Outside dimensions...

Страница 19: ...September 2012 www chroma q com 4 2 Gel String Schematic 646 mm 0 1 5 25 44 0 1 16 203mm 8 203mm 8 609mm 24 Correct way of taping the gel frames Incorrect way of taping the gel frames Detail of taping...

Страница 20: ...M8 Plus User Manual 19 V1 3 September 2012 www chroma q com 4 3 Parts Schematic...

Отзывы: