The display shows the current DMX address (between 1-512).  

To alter the address, press UP or DOWN button once to increment or decrement the value; hold down the UP or DOWN for 
fast increments and decrements of the value. 

(See also: ‘Remote Operation’ later in this section.) 

 

Fan speed mode (Fn) 

This mode is used to set the gel cooling-fan speed of the unit. This feature can be used in environments where a lower noise 
level is required, although this may decrease gel string life. 

The display shows the current gel cooling fan speed. There are four fan speeds, 1 is the slowest and 4 is the fastest. 

Press UP or DOWN once to increment or decrement the value. 

(See also: ‘Remote Operation’ later in this section.) 

 

Gel saver mode (GL) 

Gel-saver mode is used to switch the gel-saving mode on or off. This feature slowly moves the chosen gel frame back and 

forward slightly so that the heat build-up is dissipated over a larger area, extending the life of the gel string. Press the UP or 

DOWN buttons once to switch between On (1) and Off (0) (the default is Off). Press hold MENU for 2 seconds to save the new 

setting. 

This feature is also available via DMX (see "Remote operation" section of this manual). 

The appropriate gel string should be installed to maximise the benefit of this mode. 

Speed mode (SP) 

This mode is used to set the scrolling speed of the unit. This feature allows the gel string to move at a higher speed, for 

more rapid changes. Use of this high speed will generate more noise from the unit. 

Press the UP or DOWN buttons once to switch between Standard (1) and Fast (2) (the default is Standard). Press and hold 

MENU for 2 seconds to save the new setting. 

This feature is also available via DMX (see "Remote operation" section of this manual). 

Display mode (dP) 

This mode is a two step feature set with the UP and DOWN button, on (1) and off (0). Default is off (0). When set to dP1 the 

display will change to diagnostic mode after 6 seconds. When set to dP0 the display will change to the diagnostic mode in 6 

seconds, then clear in another 6 seconds, making 12 seconds till auto-blackout. The display will return to diagnostic mode 

with the first button press and will do the action of the second press. 

Remote Operation mode (ro)  

This  mode  is  used  to  switch  between  the  different  remote  operation  modes  in  the  unit.  The  use  of  these  different  modes 

greatly enhances the versatility of the unit by giving the user remote control of some functions. 

There are three remote operation modes: 

 

Mode 1 = 

Single-channel DMX operation. The

 

channel controls the colour selection. 

Mode 2 = 

Dual-channel DMX operation. The 1

st

 channel controls the colour selection. The 2

nd

 channel controls the 

fan speed; 

0-24%= Fn 4(fast), 25-49% = Fn3, 50-74% = Fn2, 75-100% = Fn1 (slow). 

Mode 3 = 

Dual-channel DMX operation. The 1

st

 channel controls the colour selection. The 2

nd

 channel controls the 

units other functions. 

These functions 

Ch. 2 Level 

  Feature 

Содержание M8 Plus

Страница 1: ...Chroma Q M8 Plus User Manual Version 1 3 September 2012 PN 114 0501...

Страница 2: ...the above e by modification repair or service by anyone other than Chroma Q who has not applied for and been approved by Chroma Q to do such modification repair or service unless the Customer provides...

Страница 3: ...make alteration to devices and their functionality without notice due to our on going research and development The Chroma Q M8 Plus has been designed specifically for the professional entertainment l...

Страница 4: ...2 Control and power cables 5 2 3 Gel Loading and Replacement 6 2 4 Mounting the unit 8 2 5 Operating the unit 9 2 6 Modes of operation 10 2 7 Troubleshooting 14 2 8 Technical overview 15 2 9 Technica...

Страница 5: ...changer Provide a minimum clearance of 0 1 meters 4 inches around air vents Do not modify fixture accessory or install other than genuine Chroma Q parts Protection from injury due to falls When mounti...

Страница 6: ...racket for 8 light blinder fixtures 2 Operation 2 1 Unpacking the unit 2 2 Control and power cables 2 3 Mounting the unit 2 4 Operating the unit 2 5 Modes of operation 2 6 Troubleshooting 2 7 Technica...

Страница 7: ...line loss c It is recommended to use a return cable for each run This will ensure balanced DC power to all units where the line is correctly terminated and all units receive power if one link of the c...

Страница 8: ...hen installing gel string 1 Place the unit on a flat surface with motor fan electronics on your right hand side assuming you re loading from tail end of the string reverse if starting from the leader...

Страница 9: ...of the gel string to the Take Up Reel TUR Follow the centre line guide scribed on the TUR 3 Apply power to the unit while holding down the MENU button The display will show the legend PAL 4 Press and...

Страница 10: ...n Decreases the mode level or value UP Button Increases the mode level or value 3 digit display Displays mode monitor or blank display Push button operation The MENU button is used to scroll through t...

Страница 11: ...enu under dP where dP0 is OFF and dP1 is ON Reset If the MENU and the UP button are pressed and held for 1 second the unit will reset to the factory default settings This feature is particularly usefu...

Страница 12: ...crolling speed of the unit This feature allows the gel string to move at a higher speed for more rapid changes Use of this high speed will generate more noise from the unit Press the UP or DOWN button...

Страница 13: ...l reset the unit to the default settings While holding down MENU and UP button for 1 second P P P Power A A A Assisted L L L Loading PAL Load Used to load a gel string into the unit Hold down the MENU...

Страница 14: ...r DOWN to switch between on 1 and off 0 See also display mode instructions remote operation Mode1 single DMX channel operation Mode 2 Dual DMX channel operation Colour Fan speed Mode 3 Dual DMX channe...

Страница 15: ...cator is off Bad Cable No DMX at Splitter PSU Check cable and DMX run from console Units run at different speeds Colour changer speed settings may be different Cable lengths are too long No cable retu...

Страница 16: ...electronics problems are usually created by external factors such as shorted cables etc The 75176 transceivers are susceptible to damage if 24VDC is present on the DMX signal lines Routine maintenanc...

Страница 17: ...M8 Plus 3 Maintenance and Storage The M8 Plus should be stored in a dry and cool environment safely secured to prevent from falling on a hard surface The unit may be exposed to dirty environments con...

Страница 18: ...M8 Plus User Manual 17 V1 3 September 2012 www chroma q com 4 Drawings 4 1 Outside dimensions...

Страница 19: ...September 2012 www chroma q com 4 2 Gel String Schematic 646 mm 0 1 5 25 44 0 1 16 203mm 8 203mm 8 609mm 24 Correct way of taping the gel frames Incorrect way of taping the gel frames Detail of taping...

Страница 20: ...M8 Plus User Manual 19 V1 3 September 2012 www chroma q com 4 3 Parts Schematic...

Отзывы: