![Christie VC-RAD 14 Select Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/christie/vc-rad-14-select/vc-rad-14-select_user-manual_2603571009.webp)
7
4.2.4 View Temperature:-
The “Heat” menu displays the current internal temperature in degrees Celsius.
Note that the tool will shut off if the temperature exceeds 90 °C until it cools
down below 80 °C.
4.2.5 Tool Model:-
The Tool Model menu shows which gearbox model is selected. The tool
model may only be changed by W. Christie.
4.2.6 Lower Limit:-
The “Lo” menu option displays the lower torque limit of the tool. This option
is normally set to 10% of the rated torque and may be increased up to 20% of
the rated torque by W. Christie
4.2.7 Upper Limit:-
The “Hi” menu option displays the upper torque limit of the tool. This value
can only be set as high as the rated maximum torque, and may be set as low
as 80% of the rated torque by W. Christie.
4.2.8 Serial Number:-
The last four digits of the unique stamped serial number are displayed in this
menu.
4.2.9 Clock and Calendar:-
The Clock menu flashes the 24-hour time when the menu heading is
displayed. You can set the date and time within the menu.
4.2.10 View Program Version:-
The program menu displays the controller firmware version. When you enter
the menu, the program version number will scroll across the screen.
Содержание VC-RAD 14 Select
Страница 15: ...13...