RRC–Request Register Count
Returns the number of registers for a specified data type, optionally on a specific page.
Syntax
RRC <RegisterType> [<PageNumber>]
Response
<Result Code> <Register Count>
page
for additional information on Result Codes
.
Arguments
Argument
Description
Values
<RegisterType>
Sets the register type.
0 (0x30) = Effect
1 (0x31) = Playitem
2 (0x32) = Not used
3 (0x33) = Not used
4 (0x34) = Command key/script
5 (0x35) = Treatment
6 (0x36) = Source
7 (0x37) = Function key
8 (0x38) = Not used
9 (0x39) = Not used
10 (0x31 0x30) = Still image
<PageNumber>
Determines the page number to return. Zero-based
-1 = Return all pages