background image

Christie MicroTiles

Serial Commands

Te c h n i c a l   R e f e re n c e

020-101547-01

Содержание RS232

Страница 1: ...Christie MicroTiles Serial Commands Technical Reference 020 101547 01 ...

Страница 2: ...en designed modified or approved by Christie for such use i Problems or damage caused by use of a projector in the presence of an oil based fog machine or laser based lighting that is unrelated to the projector j For LCD projectors the warranty period specified in the warranty applies only where the LCD projector is in normal use which means the LCD projector is not used more than 8 hours a day 5 ...

Страница 3: ...c Array Configuration 6 AGN Alignment 6 CCM Color and Brightness 7 CNG Configure Array 8 DPW Display Window 8 EDD EDID 8 ITP Internal Test Pattern 9 LNQ Link Quality 11 LST List Displays 12 MLR Mullion Reduction 13 MMP Manual Mapping 13 NET Network Setup 14 PRI Priority 17 PWR Power 17 RST Reset 19 SAR Subarray 19 SEL Select 21 SHP Sharpness 21 TMD Time and Date 22 UCR Uniformity Correction 23 VDM...

Страница 4: ...n RS232 connection to remotely access display controls and image setups issue commands or queries and receive replies 1 Connect one end of a null standard 9 pin female to female modem cable to the projector RS232 port 2 Connect the other end of the null standard 9 pin female to female modem cable to a computer Terminal Program Setup To setup terminal program for proper echoing see below TeraTerm S...

Страница 5: ...rties ASCII setup Send line ends with line feeds checked File Properties ASCII setup Echo typed characters locally checked TCP You can also use TeraTerm to connect to the TCP port of Microtiles ECU File New connection TCP Host ECU IP address File New connection TCP Telnet unchecked File New connection TCP TCP port 3002 ...

Страница 6: ...Commands i The commands and parameters are case sensitive Use capital letters for the commands Send a carriage return r or new line n at the end of your output this will start the processing of command Before executing a command that applies to selected tiles or ECUs you must execute the SEL command to identify the tiles or ECUs See SEL Select on page 21 Command Description Values AAC Returns the ...

Страница 7: ...the color match mode to tile mode CANVAS Sets the color match mode to canvas mode CCM BRTM Returns the brightness mode for the array CCM BRTM mode Sets the brightness mode ECON Economy Brightness Mode FIXED Fixed Brightness Mode MAX Maximum Brightness CCM TBRT Returns the target brightness when in fixed brightness mode CCM TBRT value Sets the target brightness in nits when in fixed brightness mode...

Страница 8: ...ets the brightness limit for Maximum Brightness CCM TCLR Returns the target gamut color space for the array This command is only available if the Color Mode is set to FIXED CCM TCLR redx redy greenx greeny bluex bluey Sets the target gamut color space for the array This command is only available if the Color Mode is set to FIXED CCM ACLR Returns the actual color gamut achieved on the canvas Comman...

Страница 9: ...o mode to display test patterns Puts a test on the screen or queries the test pattern currently displayed Parameters Control Group Unsaved Subclass Power Up Access Level Operator Command Description Values EDD Returns the custom EDID from the selected ECUs EDD horizontal vertical framerate Sets the resolution and framerate horizontal Sets the horizontal resolution in pixels vertical Sets the verti...

Страница 10: ...tal Ramp Vertical Ramp and Diagonal Ramp test patterns 0 Default to 100 ITP RMPS slope Defines the slope used for the Horizontal Ramp Vertical Ramp and Diagonal Ramp test patterns 1 Default to 5 ITP RMPL grey level Defines the starting top left grey level used for the Horizontal Ramp Vertical Ramp and Diagonal Ramp test patterns This setting has no effect when the ramp is moving such as ITP RMPM i...

Страница 11: ... 0 OSD full field test pattern 1 None 2 Checkerboard 3 Color square on a black 4 Full field grid 5 Full intensity color bars 7 Full field inverted checkboard 8 13 Point 9 Grayscale 16 ITP pattern Displays a tests pattern on the display 0 Off 1 Grid 2 Grayscale 16 3 White 4 Flat grey 5 Black 6 Checker 7 13 Point 8 Color Bars 11 Aspect Ratio 12 Edge Blend 14 Boresight Disable test patterns revert to...

Страница 12: ... not increasing Rapidly increasing error count usually indicates cabling issue Get the link quality of the MicroTiles MMP LIST The following results are displayed Index Serial Ch1 Error Count Ch2 Error Count 0 0x0023ed84 0 0 1 0x0023effb 30 0 2 0x0024ccc3 0 8 3 0x0024cfd9 0 32 This indicates tile 1 has 30 errors on Ch1 HSSL Port 1 and tile 3 has 32 errors on Ch2 HSSL Port 2 A small amount of error...

Страница 13: ...turned I A X Y Serial Left Bottom Port0 Port1 Source0 Source1 0 0 0 0 0x0023cf00 0xffffffff 0x0024ccc3 0x0024ccc3 0 0x0023effb 1 0x0000000 0 0x0024e89d 1 0 0 2 0x0023effb 0xffffffff 0xffffffff 0x0024e89d 0 0x0023cf00 1 0x0024e89 d 0x00000000 2 0 0 1 0x0024ccc3 0xffffffff 0x0023effb 0x0023cf00 0 0x00000000 0 0x0024e89 d 0x00000000 Command Description Values MLR Returns the current mullion gain and ...

Страница 14: ...ol Group Configuration Preference Subclass Power Down Access Level Admin Command Description Values MMP LIST Lists all manually mapped tiles MMP ADD index array x y Adds a manually mapped tile index The number of the MicroTile in the MicroTiles list array The index of the array x The x coordinate y The y coordinate MMP DEL index Deletes a manually mapped tile index The number of the manually mappe...

Страница 15: ...ector This can help simplify broadcast searching by organizing projectors into groups particularly if a large number of projectors are on the same local network NET DHCP 1 Enables DHCP To turn off DHCP support switch to a static IP by using the base command NET ETH0 Returns the projector IP address Read only NET GATE Returns the projector gateway address Read only NET HOST name Sets the name for t...

Страница 16: ...0 NET MODE Retrieves the Network IP address mode Auto or Manual NET MODE value Sets the network IP addressing mode Auto Obtains the IP address automatically Manual Sets the IP address to the value identified by the user Set new IP address on the first ethernet controller NET ETH0 192 168 1 35 Set the gateway NET GATE 192 168 0 1 Set the subnet mask on the first ethernet controller NET SUB0 255 255...

Страница 17: ... Parameters Control Group Unsaved Subclass Power Down Access Level Operator Get default gateway NET GATE 192 168 0 1 NET GATE Set the Port number NET PORT 3002 Get the Port number NET PORT 3002 NET PORT Set the static IP address to 192 168 1 100 with a netmask of 255 255 255 0 and no gateway NET 192 168 1 100 255 255 255 0 Turn on DHCP support NET DHCP 1 Command Description Values PRI Displays the...

Страница 18: ... mode 1 Power on to Lamps On mode 10 Cool down lamp is cooling down controlled by lamp Read only 11 Warm up lamp is warming up controlled by lamp read only 20 AutoShutdown mode 1 Read only 21 AutoShutdown mode 2 Read only 22 AutoShutdown mode 3 Read only 23 Emergency shutdown ending in Power off Command Description Values PWR 0 1 Turns the projector on or off 0 Turns the projector off 1 Turns the ...

Страница 19: ...WR Turn the lamp and all electrical power on PWR1 Set the projector to Standby mode PWR0 Reboot into failsafe mode PWR RBFS 1 Turn on the projector PWR 1 Turn off the projector PWR 0 Return current state of the power to the projector PWR PWR 000 Power Off Command Description Values RST Resets all selected tiles and ECUs RST ECUS Resets all selected ECUs The prefix and has no effect on the RST ECUS...

Страница 20: ...L_ ALL Deletes all the subarrays SAR ENBL index Enables a subarray index The number of the subarray SAR DSBL index Disables a subarray index The number of the subarray SAR DPWN index x y width height Sets the display window index The number of the subarray x x offset in decimal points 0 0 1 0 y y offset in decimal points 0 0 1 0 width width of the display window in decimal points 0 0 1 0 height he...

Страница 21: ...em indexes for the selected displays SEL ECUS ALL Selects all ECUs SEL ECUS NONE Deselects all ECUs SEL ECUS number Selects the ECU by number SEL TILS ALL Selects all tiles SEL TILS NONE Deselects all tiles SEL TILS number Selects the tile by number Command Description Values SHP Returns the current sharpness of the selected MicroTiles SHP 50 Sets the sharpness to 50 on all MicroTile Get the sharp...

Страница 22: ...gardless of the LOC TIME setting time String in the following format hh mm ss TMD DATE date Sets the date for the clock date String in the following format YYYY MM DD TMD TIME Returns the local time from the selected ECUs In the results indicates the current ECU and m indicates the master ECU TMD TIME hh mm ss Sets the local time in a 24 hour clock format TMD DATE Returns the local date from the s...

Страница 23: ...168 228 45 0x0024e999 17 50 45 Get the local time TMD TIME Set the time to 3pm TMD TIM 15 00 00 65535 00000 FYI0916 Setting Time to 15 00 00 Get the date to January 17th 2015 TMD DATE 2015 01 17 65535 00000 FYI 916 Setting Date to 2015 01 17 Command Description Values UCR Returns the uniformity correction settings for the display UCR 0 1 Changes the uniformity correction settings for the display 0...

Страница 24: ...mands Command Description Values VDM 0 1 2 Sets the video mode on the selected MicroTiles 0 Video 1 Unscaled OSD 2 Scaled OSD Subcode Description Values VER Returns the firmware and hardware version of the selected MicroTiles and ECUs VER TILS Returns the firmware and hardware version of the selected MicroTiles VER ECUS Returns the firmware and hardware version of the selected ECUs Command Descrip...

Страница 25: ... Seoul ph 82 2 702 1601 Japan Tokyo ph 81 3 3599 7481 India ph 91 080 6708 9999 Germany ph 49 2161 664540 France ph 33 0 1 41 21 44 04 Eastern Europe and Russian Federation ph 36 0 1 47 48 100 China Shanghai ph 86 21 6278 7708 China Beijing ph 86 10 6561 0240 Brazil ph 55 11 2548 4753 Australia ph 61 0 7 3624 4888 Worldwide offices Italy ph 39 0 2 9902 1161 Consultant offices Canada Kitchener ph 5...