Service setups
HS Series 2K Service Manual—DWU1612-HS,DWU2022-HS
37
020-001790-01 Rev. 1 (03-2020)
Copyright ©2020 Christie Digital Systems USA Inc. All rights reserved.
• The IP address: 192.168.0.100 (default)
• The Subnet Mask: 255.255.255.0 (default)
2. In Network settings, set the projector IP address.
See
Performing a network function test on the network port
3. Read the projector information.
See
Performing a network function test on the network port
Performing a RS232 and video function test on
HDBaseT port
To perform the RS232 and video function test, complete the following steps.
1. Connect the CH-506TX, projector and PC as shown in step 5.
2. Switch the signal source to
HDBaseT
.
3. On the IR remote keypad, press the
Menu
button and select
Configuration
>
Communica-
tions
>
Serial port
>
HDBaseT
.
4. Set the PC Baud Rate to
115200
.
5. Input the RS232 command (SYS?).
The projector returns the following: (SYSx).
On-screen display functionality inspection
All on-screen display functions must be checked for functionality.
ID
Check item
Check point
1
General
When the on-screen display menu is displayed, no visible peaking, ringing,
streaking, or smearing artifacts are on the screen.
RJ45 to HDBaseT port
RS232 to PC
Power
HDMI input