APS Series Technical Reference
6
020-103593-01 Rev. 1 (07-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Communicating with Christie APS
Series
Understand the information and procedures for communicating with Christie APS Series from a remote
location. You can communicate with the projector through the RS232 IN port.
Model name
•
LWU560-APS
•
LWU660-APS
Connecting to the projector RS232 IN port
Communicate with the projector through the RS232 IN port.
1.
Connect one end of a null standard nine-pin female to female modem cable to the projector RS232 IN
port.
2.
Connect the other end of the null standard nine-pin female to female modem cable to a computer.
3.
Connect PIN 2 to PIN 3, PIN 3 to PIN 2 and PIN 5 to PIN 5.
RS232 communication parameters
The RS232 IN port has several communication parameters.
Parameter
Value
Default baud rate
19200
Parity
None
Data bits
8
Stop bits
1
Flow control
None