Troubleshooting
35
LWU900-DS/LHD878-DS/LWU755-DS
User's Manual - Instant Stack Guide
020-001617-01 Rev. 1 (12-2018)
LIT MAN USR DS Series ISG
7. Troubleshooting
(continued)
Issues
Cases not involving a machine defect
Reference
page
The STACK
menu does not
work.
The settings on the projectors are not set
for the Intellectual Stack feature.
Check the following settings on the Main and
Sub projectors.
- STANDBY MODE in SETUP menu:
NORMAL
- COMMUNICATION TYPE under
COMMUNICATION in SERVICE menu:
OFF
- STACK LOCK in SECURITY menu: OFF
5
The projector
does not respond
to the remote
control.
The remote control is pointed at the Sub
projector.
When operating in Intellectual Stack, only
the Main projector is capable of receiving the
remote control signals. Therefore, point at the
Main projector when using the remote control.
3
The images are
either out of
focus or not well-
superimposed.
The two images are not superimposed
correctly.
Adjust to superimpose the images with the
ZOOM, FOCUS and LENS SHIFT features.
If necessary, adjust 3D KEYSTONE and
KEYSTONE as well.
6
11
The images
from the two
projectors do not
superimposed
even after
performing fine
adjustment.
There are some adjustment differences in
the two images.
Try to resolve the problem with the following
measures.
Operating Guide
→ Using the
automatic
adjustment feature
→ SIZE AND
POSITION menu
→ AUTO IMAGE,
H POSITION or
V POSITION
→ INPUT menu
→ RESOLUTION
- Press the AUTO button on the remote
control or execute AUTO IMAGE on each of
the projectors.
- Adjust H POSITION and V POSITION on
each of the projectors.
- Check the RESOLUTION setting in the
INPUT menu, and change to the same
setting if the setting differs between Main
and Sub.
If you require more information on Instant Stack, consult your dealer.
Содержание 121-057103-01
Страница 1: ...DS Series LWU900 DS LHD878 DS LWU755 DS User s Manual Detailed Instant Stack Guide 020 001617 01...
Страница 2: ......
Страница 39: ......