Tools Needed and Supplies
57" Endura
®
Flush Mount Fan Installation & Operator’s
6
MV2423F
Fans can be installed with the Extension Box through the wall or outside the wall. The Figure below shows dimensioning
for both installations.
Tools Needed and Supplies
3/8", 1/2", and 7/16" sockets or wrenches, side cutters, 1/4" nut driver, motor power cord, wire nuts / terminals, 5/32"
allen wrench (un-assembled)
New Installation Planning
70-1/8
" [178.1cm]
8-3/4"
21-1/16"
[53.5cm]
[22.1cm]
4-5/16"
[10.9cm]
!Important:
Provide Shelter over Cones in areas where
snow or ice could cause damage. CTB Inc. Warranty
Does Not
cover damage from external sources.
63-3/16" [161.1cm]
61-7/16" [
156cm]
Outside the Wall Installation
59-1/4" [15
0.4cm] Square
Through Wall Installation
56-1/2"
[143.51m]
Outside Wall
"X" =59-1/2" [151.1cm] Minimum
Flat Mounting Surface Required
X
X
Important!
Fan Mounting
Surface must be
Flat.
Frame Rough Opening
1-1/2"
[3.8cm] Typ.
For Outside Wall Mounting
(Through Wall or Outside Mounting)
Outside Flange