Safety Instructions and Warnings

Chore-Tronics NV Control

6

MT1558B 

Read all instructions in this manual carefully, before operating the Control.

Ground all electrical equipment for safety. 

The installation of the Control must be done by an authorized technician /

installer

All wiring should be done by a qualified electrician in accordance with local and 

national electrical codes.

Electrical current to control must be hard wired into breaker box, eliminating any 

receptacle.

Control should be located in an area that is protected from the elements.

Front cover must be kept closed at all times except when front panel is in use.

Control should be mounted securely to an internal wall or to a board that is 

mounted to a wall.

It is recommended that an audible warning device (i.e. siren, phone dialer, etc.) 

be used to inform grower of unacceptable conditions.

•  Check the Control regularly for possible malfunctioning. Notify your local 

Chore-Time distributor of any problems.

It is recommended that the control be energized year round. This will help the 

interior of the control to stay dry, and extend the life of the memory backup 

battery. If the house is empty, use the manual switches to discontinue the function 

of equipment wired to the control.

• Check your Control regularly for proper functioning. This control is 

manufactured to provide reliable operation as well as an alert system to notify 

you of system failures. However, this cannot be 100% guaranteed because of 

circumstances that are beyond Chore-Time’s control. Since this control is 

helping to provide a living environment for livestock, it is recommended that a 

Back-Up system be provided in the unlikely event of a system failure. Failing to 

provide a Back-Up will be viewed as the user’s willingness to accept the risk of 

that loss. 

• Chore-Time takes no responsibility for any possible damage as a result of 

improper settings and non or partially functioning installation.

• Chore-Time takes no responsibility for any possible damage due to failure, 

damage, or malfunction resulting from misuse, abuse, negligence, alteration, 

accident, lack of proper maintenance, improper or insufficient power sources or 

electrical connections, impact of foreign objects, tornado, hurricane, other 

violent storm, flood, fire, pollutants, chemicals, acts of God, or other causes 

outside the reasonable control of Chore-Time. 

• Do not use running water or high pressure washers on or around your control.

Safety Instructions and Warnings

<Caution>

! Danger !

Содержание Chore-Tronics Natural Ventilation

Страница 1: ...MT1558B MT1558B August 2014...

Страница 2: ...to you This warranty gives the original purchaser specific legal rights You may also have other rights based upon your specific jurisdiction Compliance with federal state and local rules which apply...

Страница 3: ...ion of Control Front Panel 9 Viewing Screen 10 Navigation Buttons 10 Edit Buttons 10 Subject Buttons 11 How to Maneuver in the Viewing Screen 12 Using the Navigation Buttons 12 Using the Edit Buttons...

Страница 4: ...future reference Distributor s Name___________________________________________________ Distributor s Address ________________________________________________ Distributor s Phone ______________________...

Страница 5: ...ating your Control If you have any questions regarding your Control please contact your local Chore Time dealer Explanation of Symbols and Special Manual Elements Cautions alert you to potential damag...

Страница 6: ...the house is empty use the manual switches to discontinue the function of equipment wired to the control Check your Control regularly for proper functioning This control is manufactured to provide rel...

Страница 7: ...isconnect device for motor loads If a load of more than 1 H P is controlled by a relay in the control additional contactors are required and some of the basic flexibility of the control is compromised...

Страница 8: ...screen s contents are affected by the answers and settings of Screen 6 2 Answer all questions and adjust settings in Screens 2 3 4 5 3 Recheck all screens to verify everything is as desired While goi...

Страница 9: ...NV Control Introduction to Control 9 MT1558B Description of Control Front Panel Introduction to Control Item Description 1 Natural Ventilation 2 Viewing Screen 3 Navigation Buttons 4 Edit Buttons 5 Su...

Страница 10: ...utton this will activate fast forward which accelerates the scrolling process The left and right arrows are used only when you are in the Edit Mode explained below and will move a cursor to an editabl...

Страница 11: ...are 6 subject keys each with an indicator light As each subject button is pressed the subject that is described beside the button will appear on the screen and the light on the other side of the butt...

Страница 12: ...up and Calibration screen for viewing appears Figure 1 At this point you can move from line to line by pushing the DOWN ARROW or the UP ARROW This will cause the text to either scroll up or down one l...

Страница 13: ...e EDIT button This activates the cursor and allows you to edit certain settings Figure 4 shows what the screen looks like Notice that the settings are highlighted when they can be edited 3 Press the o...

Страница 14: ...text choices 6 If two or more editable settings are on the same line the left and right arrow buttons will be used to move between those positions To exit the Edit Mode Press the EDIT key This will ta...

Страница 15: ...Chore Tronics NV Control Relay Assignment 15 MT1558B Actual House Layout Relay Assignment Relay Device Controlled 1 2 3 4...

Страница 16: ...rent temperature from sensor 1 2 Current temperature from sensor 2 optional Set Temperature 1 1 Set Temperature 1 this is the desired temperature that you chose to operate your house at The control wi...

Страница 17: ...alarm limit If you are in an alarm condition the light next to the alarms button will flash By pressing button 4 you will be advised as to what the alarm condition is The alarm possibilities are as fo...

Страница 18: ...operate the curtain manually 1 Aut if this is showing this indicates that the control is operating the equipment automatically 2 To operate manually press the EDIT button change Aut to Man move the c...

Страница 19: ...ain curtains separately and using the optional second sensor then answer yes If your answer is no then all references to the second sensor are removed 4 Curtain Speed here is where you tell the contro...

Страница 20: ...amps 35 Locked Rotor Start Amps 1000 W Incandescent Light Load 120 Vac External Battery Input To temporarily operate outputs manually Voltage 24 Vdc Load 6 A max Temperature Sensors NTC Thermister ra...

Страница 21: ...of your string at the end or between Controls but not to more than one Control as shown in the Figure 12 below PC Connection Overview Figure 12 PC Connection Overview FNET Connection Typical I O Boar...

Страница 22: ...nothing under any condition and the indicator lights are off The fuse for incoming power is blown The circuit breaker supplying power to the control is tripped The power supply or I O board is bad Th...

Страница 23: ...Chore Tronics NV Control Wiring Diagram 23 MT1558B Natural Ventilation Control Wiring Wiring Diagram...

Страница 24: ...Parts Listing Chore Tronics NV Control 24 MT1558B Parts Listing 1 2 3 4 5 6 7 8 9 10 23 12 13 9 11 22 14 15 18 19 20 21 24 26 25 25 26 27 28 29 30 16 31 17...

Страница 25: ...lon Spacer 43383 12 75 Nylon Standoff 42530 13 10 Pin 250mm Flat Cable 42510 14 16 Pin 210mm Flat Cable 41978 15 16 Pin 150mm Flat Cable 42239 16 NV Eprom Chip 42229 17 Temperature Sensor 40741 18 RM4...

Страница 26: ...ecs Updated Parts Pages Contact your nearby Chore Time distributor or representative for additional parts and information Chore Time Group A division of CTB Inc PO Box 2000 Milford Indiana 46542 2000...

Отзывы: