Chore-Tronics NV Control
Operation and Description of Function Settings
19
MT1558B
Setup
This is probably the most important screen in your control. This is the area that
configures your control to meet the needs of your specific house management style.
This setup should be done by a certified installer or distributor technician.
Figure 11.
1.
House Number
- this is where you identify the house (barn) where the control is
being setup.This is important when a PC is part of your system.
2.
Temperature Units
- Choose between Fahrenheit or Celsius temperature
readings.
3.
Main 2 Used
- if you are operating your main curtains separately and using the
optional second sensor, then answer yes. If your answer is no, then all references
to the second sensor are removed.
4.
Curtain Speed
- here is where you tell the control the speed of the curtain
operator. To do so, with the open switch, time how long it takes for the curtain to
travel 18 inches. Insert this number by using the
Edit
buttons.
5.
Sensor Calibration
- sensors should not require calibration. You can define the
readings if desired by using an accurate device to check the sensors. If you find
that there is a discrepancy, simply insert the temperature your accurate device is
reading.
6. This area is for troubleshooting purposes and is
not editable
.
Figure 11. Setup Screen.
1
House Number 1
°F
Main 2 used Yes
spd 18in/90 sec
1T000.0 Cor 0.0
2T000.0 Cor 0.0
2
5
3
4
6