Setup and Calibration - continued

All setups are performed in the 

Edit Mode

 with the use of the 

Navigation Buttons

 to move you around to editable positions and the 

(+) and (–) buttons to make changes and to answer questions.

1.

House # - this is where you identify the house (barn) that the control is being 
setup.This is important when a PC is part of your system.

2.

Temperature Units - choose between Fahrenheit or Celsius temperature 
readings. 

3.

Units of Measurement - metric or nonmetric

4.

Clock Type - if you want to have time of day represented in a 12 hour clock (a.m. 
and p.m.), or a 24 hour clock format.

5.

House Equipped For - answer the following questions by choosing “yes” or 
“no”. These answers will configure your house and inform the control what it has 
to do. For instance, if you answer “no” to natural, then all references to natural 
ventilation will be removed from the screens. If your management practices and 
equipment is changed in the future, you can always reinstate natural by changing 
the “no” to “yes”.

6.

Curtain Speeds - if you have answered “yes” to natural, then you will have to 
tell the control the curtain speed(s). To do so, with the open switch, time how 
long it takes for the curtain to travel 18 inches. Insert this number by using the 
Edit buttons. Repeat the same steps if you have a separate control for your 
number 2 main curtain, or tunnel curtain.

The actual curtain opening will be the movement 

less

 the full closed 

curtain overlap.

7.

Curtain Movement - now that your main curtain speed(s) are entered, you can 
choose where you want your first curtain opening movement, and you can adjust 
what you want the full opening movement to be. This is done by simply inserting 
the number of inches you have chosen.

8.

Number of Fans - insert the minimum number of fans you want to operate while 
in the tunnel mode (available only on Model 16)

9.

Water Meter Calibration - enter the volume of water represented by each 
electrical signal received from your water meter (if used).

From this point on, we recommend that you use the accompanying 
house diagram to layout the equipment and assign them numbers. 
This will coincide with how these devices are wired into the relay 
panel.

{Note}

*

{Note}

*

{Note}

*

9/9/98

Содержание Chore-Tronics Model 16

Страница 1: ...MT1554A August 1998...

Страница 2: ...ical power surges or interruption of electricity shall not be considered defects under this warranty 5 This warranty applies only to systems for the care of poultry and livestock Other applications in...

Страница 3: ...eration 12 Power Mode 12 Natural Mode 12 Tunnel Mode 12 Introduction to Control 13 Description of Control Front Panel 13 Viewing Screen 14 Navigation Buttons 14 Edit Buttons 14 Security 15 Subject But...

Страница 4: ...Actual House Layout 32 MS Board Dip Switch Positions 36 Variable Speed Dip Switch Positions 37 Technical Specifications 38 PC Connection Overview 39 Off Site PC Connecting to On Site PC with Controls...

Страница 5: ...ng information about your Product Keep this manual in a clean dry place for future reference Distributor s Name___________________________________________________ Distributor s Address _______________...

Страница 6: ...ting your Control If you have any questions regarding your Control please contact your local Chore Time dealer Explanation of Symbols and Special Manual Elements Cautions alert you to potential damage...

Страница 7: ...rgized year round This will help the interior of the control to stay dry and extend the life of the memory backup battery If the house is empty use the manual switches to discontinue the function of e...

Страница 8: ...is controlled by a relay in the control additional contactors are required and some of the basic flexibility of the control is compromised It is very important that the owner integrator understands th...

Страница 9: ...temperature conditions 2 Answer all questions and adjust all settings in Screen 12 In this screen the relay numbers are associated with the output names in the drawing on page 32 This must be done fi...

Страница 10: ...perature rise HEAT ZONE Relay contacts close supplying power to the equipment on temperature fall MT1553 01 4 98 4 2 3 5 1 Key Description 1 Output Off 2 Fan Off temp falling 3 Fan On temp rising 4 Ou...

Страница 11: ...mers 1 The first type is only used for COOL outputs It modulates turns on and off a COOL output above the COOL output s on temperature 2 The second type of timer is used on EXH FAN STIR FAN TUN FAN Mo...

Страница 12: ...Initial Setup Chore Tronics Model 16 8 Control 12 MT1554A 1 6 99 Modes of Operation TUNNEL 5 98 POWER 5 98 NATURAL 5 98 Power Mode Natural Mode Tunnel Mode 9 9 98...

Страница 13: ...554A Description of Control Front Panel Introduction to Control Item Description 1 Model 16 Control Shown 2 Viewing Screen 3 Navigation Buttons 4 Edit Buttons 5 Relay Switches 6 Subject Buttons Model...

Страница 14: ...or down arrow button this will activate auto repeat which accelerates the scrolling process The left and right arrows are used only when you are in the Edit Mode explained below and will move a curso...

Страница 15: ...e of the button will be lit After viewing that subject for five minutes and if no other buttons are pressed the control will automatically return to the Current Conditions screen An explanation of eac...

Страница 16: ...tion screen for viewing appears Figure 1 At this point you can move from line to line by pushing the DOWN ARROW or the UP ARROW This will cause the text to either scroll up or down one line at a time...

Страница 17: ...If more information is needed please turn to the operation section page 36 This activates the cursor and allows you to edit certain settings Figure 4 shows what the screen looks like Notice that the s...

Страница 18: ...es 6 If two or more editable settings are on the same line the left and right arrow buttons will be used to move between those positions To exit the Edit Mode Press the EDIT key This will take you out...

Страница 19: ...lace of a temperature 5 this indicates that the sensor is a control sensor If more than one appears the control temperature will be the average of those sensors 6 Static Pressure indicates the current...

Страница 20: ...his indicates if the set temperature curve is activated this function is activated in the Set Temp Curve screen Button 8 If on then the curve will make adjustments automatically to your temperature If...

Страница 21: ...s can be re assigned for example if you feel a particular fan is coming on too frequently due to its position in the temperature order 3 Off Temperature Here is where you enter the off values for cool...

Страница 22: ...u enter the start time that you want that particular feeding cycle to begin This can be shown in twelve or twenty four hour time see Setup screen button 12 3 Run Time this is where you enter the run t...

Страница 23: ...temperatures of the mode control sensor s recorded in your house for each of the past six days The time at which these temperatures occurred is also shown Water Usage 3 This is the water usage for th...

Страница 24: ...ossibilities are as follows Maximum relative temperature Maximum temperature Minimum relative temperature Minimum temperature Sensor failure Failed potentiometer Maximum static pressure Minimum static...

Страница 25: ...ure and minimum temperature limits work in the same way as the maximum limits 7 High static pressure is the upper limit that you set to activate the alarm 8 Low static pressure is the lower limit that...

Страница 26: ...nuously calculated and is updated in 1 degree increments The set temp in screen 2 can be changed while the curve is on This shifts the curve by the amount of change Changing the set temp back to the c...

Страница 27: ...ngs 27 MT1554A Variable Speed 1 Current Speed this tells you the current speed of each variable speed output 2 Minimum Speed this allows you to set the minimum speed allowed for each variable speed ou...

Страница 28: ...ow this value while in power mode Tunnel Mode the control will close the tunnel curtain if the static pressure decreases below this value while in tunnel mode In all cases the control opens or closes...

Страница 29: ...yesterday s settings Edit the no to yes and confirm your choice as the screen will direct you 2 This allows you to change every setting of every screen to what has been previously stored as the insta...

Страница 30: ...house management style This setup should be done by a certified installer or distributor technician Figure 15 Important A full understanding of what this screen does is essential before modifying it...

Страница 31: ...always reinstate natural by changing the no to yes 6 Curtain Speeds if you have answered yes to natural then you will have to tell the control the curtain speed s To do so with the open switch time ho...

Страница 32: ...position of Main 1 and Main 2 curtains if used 2 Indicate position of Sensors 3 Fill in the list of relay numbers with device s each is controlling Relay Device Controlled 1 2 3 4 5 6 7 8 9 10 11 12 1...

Страница 33: ...4 4 4 4 4 2 2 1 C 1 5 4 4 4 4 4 5 4 4 4 4 4 4 3 4 4 4 4 4 3 4 4 4 4 4 3 4 4 4 4 4 3 4 4 4 4 4 3 4 4 4 4 4 4 3 4 4 4 4 4 4 3 3 3 4 3 4 0 4 4 4 4 4 0 4 4 4 4 4 0 4 4 4 4 4 4 0 4 4 4 4 4 4 H 4 4 4 4 4 H...

Страница 34: ...n of Function Settings Chore Tronics Model 16 8 Control 34 MT1554A 1 6 99 Setup and Calibration continued 2 1 1 2 1 2 1 1 2 1 5 8 5 5 8 5 2 C 1 1 2 C 1 E 1 Figure 16 System Setup and Calibration Scree...

Страница 35: ...will be indicated by Sensors can be assigned to more then one output 16 Assign Backup you now have to assign a backup sensor to the assigned sensors in the event of a sensor failure This is especiall...

Страница 36: ...eed Clock button when asked for the access code From the factory the Access Code is 1111 This is a special number which causes the control to not ask you for the access code when you first press the E...

Страница 37: ...ngs 37 MT1554A Variable Speed Dip Switch Positions 1 Switch position for first variable speed module 2 Switch position for second variable speed module Since variable speed modules are added in the fi...

Страница 38: ...Technical Specifications Chore Tronics Model 16 8 Control 38 MT1554A 1 6 99 This Information is to follow Technical Specifications 9 9 98...

Страница 39: ...Chore Tronics Model 16 8 Control PC Connection Overview 39 MT1554A Off Site PC Connecting to On Site PC with Controls PC Connection Overview 9 9 98...

Страница 40: ...PC Connection Overview Chore Tronics Model 16 8 Control 40 MT1554A 1 6 99 On Site PC with Controls 9 9 98...

Страница 41: ...Chore Tronics Model 16 8 Control PC Connection Overview 41 MT1554A Off Site PC with Controls 9 9 98...

Страница 42: ...lights are off The fuse for incoming power is blown The circuit breaker supplying power to the control is tripped The power supply or I O board is bad The KD board is defective The flat cable from th...

Страница 43: ...Chore Tronics Model 16 8 Control Wiring Diagram 43 MT1554A This information is to follow Wiring Diagram 9 9 98...

Страница 44: ...Wiring Diagram Chore Tronics Model 16 8 Control 44 MT1554A 1 6 99 Wiring Diagram continued This information is to follow 9 9 98...

Страница 45: ...SCM 8 2 Switch Circuit Board Model 8 41309 41308 4 IOCM 1 3 Control Module Model 16 IOCM 1 2 Control Module Model 8 41321 41311 5 RM 8 Relay Circuit Board 8 relays 41306 6 RM 8 Relay Circuit Board Mod...

Страница 46: ...Time distributor or representative for additional parts and information CTB Inc P O Box 2000 Milford Indiana 46542 2000 U S A Phone 219 658 4101 Fax 800 333 4191 EMail ctb ctbinc com Internet http ww...

Отзывы: